Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J0H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J0H4-D10

    This molded case circuit breaker features a J frame design with a rated current of 100 A. It operates effectively at a rated insulation voltage of 1000V and withstands impulse ratings of 8 kV. This br

    Available
    Call
  • 140G-J0I3-D15 from the 140G MCB series.
    Allen Bradley

    140G-J0I3-D15

    This molded case circuit breaker is housed within a J-frame and operates effectively with a rated current of 150 A. It maintains a rated insulation voltage of 1000V and an impulse withstand voltage of

    Available
    Call
  • 140G-J0I4-C40 from the 140G MCB series.
    Allen Bradley

    140G-J0I4-C40

    This molded case circuit breaker features electronic LSIG protection and is equipped with four poles. It has a rated current value of 40 A and sustains a rated insulation voltage of 1000 V and an impu

    Available
    Call
  • 140G-J2C4-C60 from the 140G MCB series.
    Allen Bradley

    140G-J2C4-C60

    This circuit breaker unit features four poles, a rated current of 60 A, and a maximum current of 250 A. The breaker's rated insulation voltage is 1000 Volts, and it can withstand impulse voltages of u

    Available
    Call
  • 140G-J2I4-D15 from the 140G MCB series.
    Allen Bradley

    140G-J2I4-D15

    This molded case circuit breaker boasts an electronic LSIG protection option and includes four poles. It operates with a current rating of 150 A and a maximum current of 250 A and supports insulation

    Available
    Call
  • 140G-J3F4-C90 from the 140G MCB series.
    Allen Bradley

    140G-J3F4-C90

    Equipped with a J frame type, this circuit breaker features four poles. It operates at a rated insulation voltage of 1000V and withstands impulse voltages of up to 8 kV. Weighing 7.72 lbs, it has a me

    Available
    Call
  • 140G-J3F4-D20 from the 140G MCB series.
    Allen Bradley

    140G-J3F4-D20

    This product features a J frame design and operates with four poles. It supports a current range of 200 Amps, ensuring robustness in varying loads. Additionally, it is rated for an insulation voltage

    Available
    Call
  • 140G-J3H4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J3H4-D10

    This circuit breaker includes four poles and effectively manages currents up to 100 A. It boasts a rated insulation voltage of 1000 volts and withstands impulse voltages of 8 kV. The weight of the uni

    Available
    Call
  • 140G-J3I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J3I3-C60

    This model features electronic LSIG protection and operates within a current range of 60 A. It has a rated insulation voltage of 1000V and is capable of withstanding impulse voltages up to 8 kV. The u

    Available
    Call
  • 140G-J3I3-D10 from the 140G MCB series.
    Allen Bradley

    140G-J3I3-D10

    This circuit breaker operates on an electronic LSIG protection scheme and supports a current range of up to 100 A. It features a rated insulation voltage of 1000 volts and can endure impulse voltages

    Available
    Call
Showing 871-880 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.