The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J0C3-C63 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C63

    This molded case circuit breaker is framed in size J and capable of managing a current range of 63 Amps. It operates at a rated insulation voltage of 1000V and withstands impulse voltages of up to 8 k

    Available
    Call
  • 140G-J0C4-C35 from the 140G MCB series.
    Allen Bradley

    140G-J0C4-C35

    This molded case circuit breaker operates with four poles and maintains a current range of 35 A. It excels in applications requiring high insulation resistance, rated at 1000 V, and can withstand impu

    Available
    Call
  • 140G-J0H4-C40 from the 140G MCB series.
    Allen Bradley

    140G-J0H4-C40

    This molded-case circuit breaker incorporates advanced electronic LSI protection and operates at a rated current of 40 Amps. The device is rated for 1000 V of insulation voltage and can withstand impu

    Available
    Call
  • 140G-J0I4-D25 from the 140G MCB series.
    Allen Bradley

    140G-J0I4-D25

    This particular molded case circuit breaker has a size J frame. It supports a rated insulation voltage of 1000 volts and can withstand impulse voltages of up to 8 kV. The device weighs 7.72 lbs. and o

    Available
    Call
  • 140G-J2C4-C40 from the 140G MCB series.
    Allen Bradley

    140G-J2C4-C40

    This circuit breaker is engineered to handle a rated current of 40 Amps and 250 Amps of maximum current. It features four poles. Its protection mechanisms include fixed thermal and fixed magnetic mech

    Available
    Call
  • 140G-J2H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J2H3-C60

    The 140G-J2H3-C60 provides excellent performance in demanding environments and operates at 60A of rated current. To ensure resilience, it is rated for 1000 V of insulation voltage and 8 kV of impulse

    Available
    Call
  • 140G-J2I3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J2I3-C60

    This breaker operates with a current rating of 60 Amps and a maximum current rating of 250 Amps. It features a J frame type and supports up to 1000V of insulation voltage and a rated impulse withstand

    Available
    Call
  • 140G-J2I4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J2I4-D10

    The 140G-J2I4-D10 breaker model features a J frame and four poles. It operates with a rated current of 100 A and is rated for insulation voltages up to 1000 V. It is also designed to withstand impulse

    Available
    Call
  • 140G-J3C4-C50 from the 140G MCB series.
    Allen Bradley

    140G-J3C4-C50

    This circuit breaker features a J frame and incorporates fixed thermal and magnetic protection mechanisms. It supports a rated current of 50 A and 250 A of maximum current. It has a rated insulation v

    Available
    Call
  • 140G-J3F4-D10 from the 140G MCB series.
    Allen Bradley

    140G-J3F4-D10

    This breaker operates effectively in a current range of 100 A and has a rated insulation voltage of 1000 volts. It withstands impulse voltages of up to 8 kV. At a weight of 7.72 pounds, the device ens

    Available
    Call
Showing 901-910 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.