Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-K15H3-D40 from the 140G MCB series.
    Allen Bradley

    140G-K15H3-D40

    This circuit breaker operates within a current range of 400 A and employs electronic LSI protection for enhanced safety. It is constructed to endure demanding environments and is rated for up to 1000

    Available
    Call
  • 140G-KC6X3 from the 140G MCB series.
    Allen Bradley

    140G-KC6X3

    This breaker model features a KC frame and is tailored for a current rating limited to the frame itself. The rated insulation voltage stands at 1000V, with an impulse withstand voltage of 8 kV. The pr

    Available
    Call
  • 140G-M0F3-D63 from the 140G MCB series.
    Allen Bradley

    140G-M0F3-D63

    This circuit breaker is designed in an M-frame format and operates with a rated current of 630 A. It features a rated insulation voltage of 1000 V and can withstand impulse voltages of 8 kV. The unit

    Available
    Call
  • 140G-M0F4-D63 from the 140G MCB series.
    Allen Bradley

    140G-M0F4-D63

    This circuit breaker uses an M frame and accommodates a rated current of 630 Amps. It features adjustable thermal and magnetic protection settings. With a maximum rated insulation voltage of 1000 volt

    Available
    Call
  • 140G-N0I4-E12 from the 140G MCB series.
    Allen Bradley

    140G-N0I4-E12

    This molded case circuit breaker is designed with a frame type N and is capable of handling a current range of 1200 A. It supports a rated insulation voltage of 1000 Volts with impulse withstand capab

    Available
    Call
  • 140G-N5K4-E12-Z1 from the 140G MCB series.
    Allen Bradley

    140G-N5K4-E12-Z1

    This circuit breaker features a frame size of N and is capable of handling a current range of up to 1200 A. Its interrupting capacity is rated at 50 kA. It also includes electronic LSIG protection fun

    Available
    Call
  • 140G-NS5I3-E12 from the 140G MCB series.
    Allen Bradley

    140G-NS5I3-E12

    With an NS frame, this circuit breaker operates effectively within a current range of 1200 A. It is rated for an insulation voltage of 1000 V and can withstand impulse voltages of up to 8 kV. The devi

    Available
    Call
  • 140G-R12I3-E25-Z1 from the 140G MCB series.
    Allen Bradley

    140G-R12I3-E25-Z1

    This model features an R frame and is capable of managing currents between 2500 A and 3000 A. With a rated insulation voltage of 1000 volts and an impulse withstand voltage of 12 kV, it is built for h

    Available
    Call
  • 140G-J0C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-J0C3-C70

    With a frame categorized as J, this circuit breaker manages an adjustable current range limited to 70 A. It can operate at a rated insulation voltage of 1000 V and withstand impulse levels up to 8 kV.

    Available
    Call
  • 140G-H3I3-D12 from the 140G MCB series.
    Allen Bradley

    140G-H3I3-D12

    The 140G-H3I3-D12 circuit breaker is designed with a frame type H and supports a current range of 120 A. It operates at a rated insulation voltage of 1000 V and is capable of withstanding impulse volt

    Available
    Call
Showing 921-930 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.