Rated 4.4 with 12 reviews

2711P-B6C20D8

Description:  PanelView Plus 6 Operator interface , 600 Terminal, with Keypad/Touch, Color display, Ethernet and RS-232 Communication, DC Powered Unit, and the Windows CE 6.0 Operating System

In Stock Ships Today 

Request a quote for 2711P-B6C20D8
Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 2711P-B6C20D8.
Exchange: Exchange credit for your defective unit available.

To Speak to a sales representative for pricing & lead time:

Phone

1-800-730-0292

International

919-205-4392


About 2711P-B6C20D8

The Allen-Bradley 2711P-B6C20D8 is a PanelView Plus 6 Terminal with an interactive, easy-to-use design that displays status information graphically. It provides users with a flexible configuration using separate display, logic, and communication modules. The 2711P-B6C20D8 comes preloaded with the FactoryTalk View Machine Edition software, and it runs by default on startup and can be configured for open access. The 2711P-B6C20D8’s HMI applications can be developed using the FactoryTalk ViewPoint and the View Studio software.
The 2711P-B6C20D8 terminal’s 5.7-inch active-matrix display screen supports both an analog touchscreen and a stainless-steel keypad for inputs. The resolution is 320 x 240 with 18-bit color graphics. It has 512 MB of RAM and 512 MB of nonvolatile memory for user storage. It has dimensions of 14 x 11 x 8 inches and weighs 6 lbs. The 2711P-B6C20D8 runs on an input voltage of 18 - 32V DC (24V DC nominal) with 70 W of maximum power consumption. It uses Ethernet and RS-232 serial ports for general communication and optional DH-485, DH+ and ControlNet modules for additional communication. The 2711P-B6C20D8 also contains 2 USB ports for connecting various external devices such as keyboards and flash drives.
The 2711P-B6C20D8 runs the Windows CE 6.0 operating system with features such as ActiveX controls, a pdf viewer, and third-party device support. It also supports SD cards for data backup and a battery-backed real-time clock for timestamping data. The 2711P-B6C20D8 is superior to previous PanelView terminals in terms of its speed, system memory, transition rate, storage space and backlight illumination. The most common Series are Series A and Series B and the most common firmware include 7.00-8.10. 

Technical specifications:

Part Number:2711P-B6C20D8
Product Line:Panelview 6 Plus
Display Size:5.7 in.
Display Color:Color
Input Type:Keypad/Touchscreen
Communication:Ethernet and RS-232
Input Power:18-30 VDC
Software:FactoryTalk View Machine Edition
Memory:256 MB RAM
Backlight:Non-replaceable
Communication Cable:2711-NC14
Shipping Weight:6 lbs.
Shipping Dimensions:14 x 11 x 8 in
Series:Series A and Series B
Firmware:7.00-8.10

FAQ

Question: Is the internal backlight replaceable on the 2711P-B6C20D8 PanelView Plus 6 Terminal?

Answer: No, 2711P-B6C20D8 does not have a replaceable backlight.

 

Question: What are the communication ports on the 2711P-B6C20D8 terminal?

Answer: 2711P-B6C20D8 PanelView Plus 6 Terminal has Ethernet and RS-232 ports in addition to 2 USB ports.

 

Question: What is the price of 2711P-B6C20D8 PanelView Plus 6 Terminal?

Answer: Submit a quote request, send us an email, or call 800-730-0292 for our best price.

 

Question: How can I repair my 2711P-B6C20D8 PanelView Plus 6 Terminal?

Answer: DO Supply offers repair services for a variety of Allen-Bradley products, such as the 2711P-B6C20D8 PanelView Plus 6 Terminal. For more information or to request a repair quote, please click here

We Can Repair Your Panelview Plus 6

We have a team of highly trained technicians that can repair your Panelview Plus 6 quickly at a great low price. To get a repair quote call 1-800-730-0292 or email sales@dosupply.com. Some of the benefits of our repair process includes:

  • Repair Turnaround of 3-5 Days for Most Panelview Plus 6
  • Rush Repairs of 1-3 Days
  • Fast Return of Your Repair via UPS, FedEx, or DHL.
  • If the item is not repairable, you can choose to have it returned to you free of charge or it can be counted as an exchange credit toward a refurbished or new unit if available.
  • Wide range of repairs that can be completed by our highly skilled technicians as shown below.
  • All Repairs Come With Our 1-Year Warranty!

 

Repair Capabilities

We Can Repair Your Hardware Failures Including:

  • Communication Failures
  • Broken Toushcreens/Keypads
  • Broken Glass
  • Displays (Dead/Dim/Lines/Missing Pixels)
  • Dead Backlights
  • Broken Housing/Bezel
  • Power Board Failures

Start UP Error Codes and Messages:

    • Load firmware image into RAM Update 1E
    • Write firmware image to storage Update A5
    • Load factory-default firmware image into RAM Restore E6
    • Write factory-default firmware image to storage Restore A5
    • Restore factory-default configuration data Restore DC
    • Firmware validation (CRC/format) failure Fatal 1E
    • Firmware failed to validate compatibility index of a firmware region Fatal 1F
    • Firmware update failure Fatal 0F
    • Firmware write to storage failure Fatal A5
    • Firmware stored image verification failure Fatal D2
    • Invalid or missing OS firmware image Fatal FF
    • Failed RAM Fatal 03
    • Stuck key Fatal 31
    • Stuck touch Fatal 3A
    • Failed backlight Fatal 3B
    • Failed to initialize restore operation Fatal R0
    • Failed restore because of invalid header in .pvb file Fatal R1
    • Failed restore because of invalid header Fatal R2
    • Failed restore because of inability to write intermediate files to terminal Fatal R3
    • Failed restored because of corrupt .pvb file Fatal R4
    • Watch dog reset Fatal 02
    • Boot loader attempting PC connection via USB device AutoTest OA
    • Boot loader loads firmware image into RAM AutoTest E6
    • Boot loader jumps to operating system AutoTest FF
    • Operating system starts up Boot G0
    • Operating system registration and initialization Init H1 - JA
    • Machine Edition registration and initialization Init K1 - MA
    • Machine Edition load and execute Init ME

Common misspellings: 2711-B6C20D8
27l1P-B6C20D8
271lP-B6C20D8
2711P-86C20D8
2711P-B6C2oD8
2711P-B6C20Db
2711P-B6C20D8X
2711PP-B6C20D8
2711PB6C20D8
//Add structured data image