CHSPT2ULTRA
Operating with a nominal discharge current of 20 kA, this surge protection device provides extensive protection with a maximum surge current of 108 kA. The device manages voltages at 150 V L-N and 300
Eaton Cutler-Hammer's CH product line includes loadcenters, loadcenter accessories, circuit breakers, and specialty products. The CH loadcenters house branch circuit breakers and the wiring that distributes power to individual circuits in an electrical system. These loadcenters have copper busses that are silver flash-plated. CH circuit breakers can be single-pole or double-pole models, and several support quick-make and quick-break switch mechanisms. Plug-on neutral devices are also included in the CH series, and these neutral devices are used to simplify system wiring and elimiate pigtail connections. Some CH loadcenters can house high-AIC main breakers.
Browse available units in our catalog of CH Loadcenters and Circuit Breakers.
Operating with a nominal discharge current of 20 kA, this surge protection device provides extensive protection with a maximum surge current of 108 kA. The device manages voltages at 150 V L-N and 300
As a thermal magnetic circuit breaker, the CH2110 provides effective interruption with a maximum rating of 10 KAIC. This unit functions in a one-phase setting and features LI functionality for both lo
This circuit breaker comprises two poles and provides thermal magnetic protection. It supports wire sizes ranging from #14 to #4 AWG and is rated for an interrupt capacity of 10 KAIC. The common trip
This circuit breaker features two poles and is classified as a Type CH Standard. It is equipped with a thermal-magnetic trip system that ensures effective protection against overloads. The breaker has
Configured specifically as a main lug loadcenter, this model is ideal for single-phase installations. It offers a robust interrupt rating at 25 kAIC and is equipped with copper bus material, ensuring
This circuit breaker belongs to the Type CH family and features a thermal-magnetic trip unit technology for effective overload and short-circuit protection. Its interrupting rating is 10 KAIC at 240 V
This circuit breaker is rated at 15 amps and has an interrupting capacity of 10 kA. It accepts wire sizes between 14 and 8 AWG, and the connection method is bolt-on with lugs. The CHB215 also includes
Featuring two poles, this circuit breaker is utilized for branch circuits and employs thermal magnetic protection strategies. It has a 10 kAIC interrupt rating. This model can accommodate a wire size
Rated for 20 amperes, this ground fault circuit breaker utilizes pigtail leads for connections. It features a thermal magnetic protection mechanism and supports both long time and instantaneous trip f
This circuit breaker features two poles and a common trip type, offering robust ground fault protection as an equipment protector. With an interrupt rating of 10 kAIC, it ensures reliable performance