EDH2225
This circuit breaker has a frame type of F and comprises two poles. It is rated for 240 VAC and 125 VDC. It exhibits an impressive interrupt rating of 100 KAIC at 240 VAC, providing reliable protectio
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
This circuit breaker has a frame type of F and comprises two poles. It is rated for 240 VAC and 125 VDC. It exhibits an impressive interrupt rating of 100 KAIC at 240 VAC, providing reliable protectio
The EDH3150 is a molded case circuit breaker specifically designed for industrial usage. This model features three poles and includes lugs for load side terminals. It can be mounted with a bolt-on con
Engineered as a part of Eaton’s Series C circuit breakers, this unit possesses a frame type classified as F. Its interrupt rating at 240 volts is rated at 42 kAIC. Designed to operate efficiently betw
This circuit breaker features three poles and utilizes an F frame type design. Protection is provided by fixed thermal and fixed magnetic trip types. It includes lugs for both line and load terminal c
This two-pole circuit breaker features a fixed thermal and magnetic trip system. It has a frame size categorized as F, and it supports an interrupt rating of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC,
This circuit breaker features both fixed thermal and fixed magnetic trip types, allowing for long-time and instantaneous trip functions that enhance protection. It has an interrupting capacity of 65 k
This circuit breaker provides a magnetic-only trip unit and can be easily mounted using a bolt-on or unit mount style. It has an impressive interrupting capacity of 65 kAIC at 240V AC and retains high
With a magnetic trip range of 1250 to 2500 amps, the HMCP400W5 is well-suited for various motor starter applications identified as NEMA Size 5. It incorporates terminal lugs for both line and load con
This circuit breaker supports three poles and is rated for 600 VAC in AC applications and 250 VDC in DC applications. The interrupting capacity is rated at 64 kA at 480 VAC. Magnetic-only trip setting
The SNT2P06K shunt trip kit is intended for compatibility with three-pole circuit breakers and supports a rated current of 250 A. It functions within control voltage specifications of 48 VDC to 60 VDC