KD2400
Operating at 400 A, this circuit breaker features two poles. Its interruption ratings are rated at 65 kAIC for 240 VAC and 35 kAIC for 480 VAC. The device uses a combination of fixed thermal and fixed
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
Operating at 400 A, this circuit breaker features two poles. Its interruption ratings are rated at 65 kAIC for 240 VAC and 35 kAIC for 480 VAC. The device uses a combination of fixed thermal and fixed
This rating plug is compatible with J-K frame types. It operates efficiently within a temperature range of 0°C to 40°C, making it suitable for standard applications. The unit can also operate at an in
Designed for left-hand mounting, this auxiliary switch instructs its operation at both 0°C and 40°C limits. It can function in environments with humidity of 80% and has an installation altitude limit
This circuit breaker features a dual-pole configuration in an F-frame type. The device utilizes a thermal magnetic trip mechanism for dependable protection. It has busbar terminations on the line side
This circuit breaker is designed with two poles and a rated trip current of 80 A. It features a thermal magnetic trip unit for effective protection. The interrupt ratings are 18 kA at 240 volts AC and
This circuit breaker is part of the Series C lineup and is characterized by its F-frame size and complete breaker design. It accommodates three poles for versatile applications and is rated for voltag
This circuit breaker includes three poles and employs a bolt-on mounting type for secure installation. Powered by a Digitrip 310 RMS electronic LSI trip unit, it supports long-time, short-time, and in
Configured with two poles, the GHB2045 features a thermal magnetic trip unit for reliable long-time and instantaneous protection. It accommodates a remarkable interrupting capacity of 65 kA at 240 Vol
This molded case circuit breaker features a design built for two poles and operates effectively in circuits up to 600 VAC and 250 VDC. It provides a trip type of fixed thermal and fixed magnetic, with