EHD2025
The EHD2025 circuit breaker is compliant for frequencies between 50 Hz and 60 Hz. It can handle an interrupting capacity of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC. It includes a load side terminal
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
The EHD2025 circuit breaker is compliant for frequencies between 50 Hz and 60 Hz. It can handle an interrupting capacity of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC. It includes a load side terminal
This circuit breaker manages voltages of up to 600 VAC and 250 VDC. It offers effective protection with an interrupting capacity of 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 35 kAIC at 600 VAC. Th
This circuit breaker features three poles and operates on a three-phase system. It utilizes thermal-magnetic trip technology for protection against overloads. The interrupting capacity is rated at 200
This circuit breaker features three poles and operates at frequencies between 50 Hz and 60 Hz. It offers high interrupt ratings: 200 kAIC at 240 V AC and 100 kAIC at 480 V AC, ensuring secure function
Designed with a frame size categorized as F Frame, the HFD3050V features three poles that allow for flexibility in three-phase configurations. The interrupting capacities are rated at 100 kAIC at 240
Eaton Cutler-Hammer's HLD3400 circuit breaker operates at a maximum voltage of 600 VAC and 250 VDC. It features thermal-magnetic trip functionality with both long-time and instantaneous trip options.
With three poles and an F-frame size, this device operates at a frequency of 50/60 Hz. It includes adjustable magnetic trip settings ranging from 45 A to 150 A and offers eight distinct adjustment pos
This motor circuit protector operates at a rated current of 400 A and has a three-pole configuration for three-phase systems. The device supports a magnetic trip range from 1250 A to 2500 A. It comes
This circuit breaker features a 3-pole configuration and is designed to operate across a frequency range of 50/60 Hz. It can withstand an interrupt capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 V
This circuit-breaker frame features three poles and is compatible with T186 trip types. It possesses a K frame designation, which supports a range of operational requirements. The interrupting ratings