EDH2100
The EDH2100 breaker's specifications include two poles and a trip type designated T186. It features a robust interrupt rating of 100 kAIC at 240 VAC, making it suitable for high fault current scenario
Series C Circuit Breakers from Eaton Cutler-Hammer provide electrical protection to switchboards, panel boards, busway devices, and motor control centers. Trip units available in this series include electronic, thermal-magnetic, and magnetic-only trip units. Series C Circuit Breakers can support maximum system current ratings of 800A, maximum AC system voltage ratings of 600V AC, and maximum DC system voltage ratings of 250V DC. The contacts in these circuit breakers support high-speed "blow open" actions. Various external accessories are available for the Series C Circuit Breakers.
Browse available units in our catalog of Series C Circuit Breakers.
The EDH2100 breaker's specifications include two poles and a trip type designated T186. It features a robust interrupt rating of 100 kAIC at 240 VAC, making it suitable for high fault current scenario
The EDH3200 has a three-pole configuration and features both fixed thermal and fixed magnetic trip types. Offering an interrupting capacity of 100 kAIC at 240 VAC, it provides robust protection. This
This device features a single pole and operates with a trip type labeled T186. It has an interrupt rating of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC, ensuring effective protection against fault cond
This circuit breaker features an F frame size with three poles. It supports voltage ratings of up to 480 VAC for AC applications and 250 VDC for DC applications. With an interrupting capacity of 18 kA
This circuit breaker features a three-pole configuration with an ampacity of 80 Amperes. It operates effectively within a frequency range of 50 to 60 Hertz. The device has an interrupt rating of 100 k
This circuit breaker operates using three poles and is part of the Series C lineup. It features a K-frame design with thermal-magnetic interchangeable trip units, allowing for enhanced versatility. Th
This circuit breaker features three poles housed in a J frame size, with a weight of 11.5 lbs. It has a magnetic trip range spanning from 2000 A to 4000 A. The AIC (Interrupting Capacity) for this mod
This series C circuit breaker features a compact F frame size and consists of three poles. It employs a magnetic-only trip unit for effective protection. The circuit breaker has a high interrupting ra
This groundable insulated neutral kit accommodates a lug range from 250–500 kcmil, ensuring diverse compatibility. It is designed for panel mounting and is compliant with UL standards. With a system v
Designed with three poles, the KD3225 breaker operates at a frequency range from 50 Hz to 60 Hz. It features a T186 trip type and has aluminum terminals for both line and load connections. This device