Free UPS Ground on All Orders!
+1 (919) 205-4392
Omron C500 C500-OA222

Product image is representative; revision or series may vary. Contact us to request a specific version.

C500-OA222

|

The Omron C500-OA222 is a TRIAC output unit featuring a compact design for effective control in various applications. It supports a maximum switching capacity of 1 A at 132 VAC with a functionality that encompasses both resistive and inductive loads.

Out of stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for C500-OA222

ManufacturerOmron
Product LineC500
Part NumberC500-OA222
Weight1.00 lbs (0.45 kg)
Description of ModuleTRIAC Output Unit
Max. Switching Capacity1 A, 132 VAC, 50/60 Hz (4 A/common, 5 A/Unit)
Min. Switching Capacity10 mA (resistive load), 40 mA (inductive load), 10 VAC
Leakage Current3 mA (100 VAC) max., 6 mA (200 VAC) max.
Residual Voltage1.2 V max.
ON Response Time1 ms max.
OFF Response Time1/2 of load frequency max.
Number of Points16 (8 points/common, 2 circuits)
Internal Current Consumption300 mA, 5 VDC max.
Fuse Capacity5 A, 250 V (two fuses)

Omron's C500-OA222 is categorized as a TRIAC output module designed for versatility and efficiency. Weighing only 0.5 kg, this unit integrates into various control systems without adding significant bulk. This output module is capable of a maximum switching capacity of 1 A, supporting voltages up to 132 VAC with operational frequencies of 50 to 60 Hz. Notably, it allows a higher capacity for common points, up to 4 A. For individual unit functions, it handles a maximum of 5 A.

The minimum switching capacity indicates that the device can operate loads as low as 10 mA for resistive loads and 40 mA for inductive loads, while it maintains functionality at voltages as low as 10 VAC. Leakage currents peak at 3 mA for 100 VAC and 6 mA for 200 VAC, ensuring reliable operation without excess loss.

Residual voltage is capped at 1.2 V maximum, contributing to efficient state changes within the system. When activated, the module demonstrates an ON response time of up to 1 ms. The OFF response time is determined by load frequency, creating efficient disengagement under operational conditions.

The unit features two circuits of 8 output points each, summing to a total of 16 points for robust application support. Its internal current consumption is rated at a maximum of 300 mA at 5 VDC. Designed with safety in mind, the module includes two fuses rated at 5 A and 250 V. Dimensions conform to the A-shape standard, allowing for easy integration into corresponding panel setups.