Free UPS Ground on All Orders!
+1 (919) 205-4392
Schneider Electric Modicon 140DIO33000C

Product image is representative; revision or series may vary. Contact us to request a specific version.

140DIO33000C

|

The Schneider Electric 140DIO33000C module is designed as an intrinsically safe discrete output solution. It operates effectively in environments up to 5000 meters and supports output specifications necessary for demanding conditions.

In Stock
Ships from Raleigh, NC
2 Year DO Supply Warranty
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Technical specifications for 140DIO33000C

ManufacturerSchneider Electric
Product TypeIntrinsically Safe Discrete Output Module
Product LineModicon
Part Number140DIO33000C
Weight32.00 lbs (14.51 kg)
Operating Altitude≤ 5000 m
ESD Resistance4 kV contact, 8 kV air
Maximum Altitude1000 meters above sea level
Operating Temperature0 to 60°C
Output TypeOpen Collector
EMF Resistance10 V/m (80–2000 MHz)
Product DestinationZone 20, 21, 22
Storage Temperature-40 to 85°C
Maximum Load Current360 mA per module, 45 mA per point
Off State Leakage Current0.4 mA per point
Output Voltage24 V
Humidity95% without condensation

The Modicon series includes the 140DIO33000C, which is classified as an intrinsically safe discrete output module. It is designed for operating altitudes of up to 5000 meters. Suitable for various hazardous locations, this module is rated for Zone 20, 21, and 22 applications. ESD protection is robust, providing resistance of 4 kV for contact and 8 kV for air discharges.

With an operating temperature range from 0 to 60°C, it can endure a variety of industrial environments. In storage conditions, it can withstand temperatures between -40 and 85°C, ensuring functionality in extreme conditions. The device also meets EMF resistance standards, maintaining stability at 10 V/m across frequencies from 80 to 2000 MHz.

The output type is open collector, with an output voltage set at 24 V. In terms of load management, it supports a maximum current of 360 mA per module, while individual points can handle 45 mA. The off-state leakage current is minimal, at 0.4 mA per point, contributing to efficient energy usage. Finally, the module is designed to operate in humidity levels up to 95%, provided there is no condensation, indicating its durability in moisture-prone areas.