The Schneider Electric 140DIO33000C module is designed as an intrinsically safe discrete output solution. It operates effectively in environments up to 5000 meters and supports output specifications necessary for demanding conditions.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Schneider Electric |
|---|---|
| Product Type | Intrinsically Safe Discrete Output Module |
| Product Line | Modicon |
| Part Number | 140DIO33000C |
| Weight | 32.00 lbs (14.51 kg) |
| Operating Altitude | ≤ 5000 m |
| ESD Resistance | 4 kV contact, 8 kV air |
| Maximum Altitude | 1000 meters above sea level |
| Operating Temperature | 0 to 60°C |
| Output Type | Open Collector |
| EMF Resistance | 10 V/m (80–2000 MHz) |
| Product Destination | Zone 20, 21, 22 |
| Storage Temperature | -40 to 85°C |
| Maximum Load Current | 360 mA per module, 45 mA per point |
| Off State Leakage Current | 0.4 mA per point |
| Output Voltage | 24 V |
| Humidity | 95% without condensation |
The Modicon series includes the 140DIO33000C, which is classified as an intrinsically safe discrete output module. It is designed for operating altitudes of up to 5000 meters. Suitable for various hazardous locations, this module is rated for Zone 20, 21, and 22 applications. ESD protection is robust, providing resistance of 4 kV for contact and 8 kV for air discharges.
With an operating temperature range from 0 to 60°C, it can endure a variety of industrial environments. In storage conditions, it can withstand temperatures between -40 and 85°C, ensuring functionality in extreme conditions. The device also meets EMF resistance standards, maintaining stability at 10 V/m across frequencies from 80 to 2000 MHz.
The output type is open collector, with an output voltage set at 24 V. In terms of load management, it supports a maximum current of 360 mA per module, while individual points can handle 45 mA. The off-state leakage current is minimal, at 0.4 mA per point, contributing to efficient energy usage. Finally, the module is designed to operate in humidity levels up to 95%, provided there is no condensation, indicating its durability in moisture-prone areas.