We offer extensive repairs for your 1336 FORCE Drives. We keep many spare parts in stock so that we can repair your 1336 FORCE Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 FORCE Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 FORCE Drives parts.

Browse 1336 FORCE Drives Repairs

Browse our catalog of repairable 1336 FORCE Drives parts to get a quote.

1336VT-B025-EOP

This drive operates on three-phase AC voltage, with ratings of 380/415/460V. The 25 horsepower rating makes it suitable for medium to heavy-duty applications. It provides continuous operation within a

Call

1336VT-B025-EOP-FA2-L1

This drive accommodates input frequencies between 50 and 60 Hz and permits output frequencies from 0 to 250 Hz. The IP00 rating indicates an open enclosure type, suitable for environments where protec

Call

1336VT-B025-EOP-FA2-L3

This AC drive operates on input frequencies of 50 or 60 Hz and delivers a current output of 34 A. The output kVA ratings vary based on voltage: 22.4 kVA at 380 VAC, 24.4 kVA at 415 VAC, and 27.1 kVA a

Call

1336VT-B025-EOP-L3

Engineered with a NEMA Type 1 / IP20 enclosure, the 1336VT-B025-EOP-L3 drive maintains operational integrity in numerous environments. Rated output currents reach up to 34 Amps continuously, ensuring

Call

1336VT-B030-EAR-FA2-L3-S1

This model features a minimum operational frequency of 50 Hz and a maximum of 60 Hz, suitable for 3-phase systems. The drive can handle an output current of 40 A and varying apparent power levels of 2

Call

1336VT-B030-EOR-FA2-L3

This series features extensive transient protection, capable of tolerating line transients up to 5,000 volts peak with a capacity of 320 Joules. Furthermore, it has defined trip settings for both over

Call

1336VT-B040-EAR-FA2-L3-S1

Designed for 3-phase systems, this drive operates at a frequency range of 50 Hz to 60 Hz. It showcases an apparent power capability of 34.2 kVA at 380 VAC, 37.4 kVA at 415 VAC, and 41.4 kVA at 460 VAC

Call

1336VT-B040-EOR-FA2-L3

This drive operates at frequencies of 50/60 Hz. It provides kVA outputs of 34.2 kVA at 380V AC, 37.4 kVA at 415V AC, and 41.4 kVA at 460V AC. It includes an open-style enclosure with IP00 rating, with

Call

1336VT-B040-EOR-L1

This drive delivers an output current of 52 amps and offers varying kVA ratings depending on the input voltage—34.2 kVA at 380V, 37.4 kVA at 415V, and 41.4 kVA at 460V. It features an open enclosure d

Call

1336VT-B040-EOR-L3

This 3-phase AC drive supports operational frequencies from 50 to 60 Hz and can deliver an output current of 52 Amps. It provides apparent power ratings of 34.2 kVA at 380 VAC, 37.4 kVA at 415 VAC, an

Call
Showing 51-60 of 72 results

About 1336 FORCE Drives

Allen-Bradley manufactures a wide variety of variable frequency drives (VFDs) in different series, and the 1336 FORCE Drive series is a series of VFDs. The VFDs are also known as adjustable frequency AC drives. These drives are mostly used for the control and regulation of torque and speed in a machine. The input voltage of the drives in this series ranges from 200 to 240 Volts AC, 380 to 480 Volts AC, or 575 Volts AC and the output voltage ranges from 0 to the input voltage. The rated power output of these drive ranges from 1 to 3 Horsepower, 7.5 to 30 Horsepower, 40 to 60 Horsepower, 75 to 125 Horsepower, 150 to 250 Horsepower, 300 to 500 Horsepower, 600 to 650 Horsepower, or 700 to 800 Horsepower. The 1336 FORCE Drive series is a microprocessor-controlled AC drive series. It is a digital drive series and it offers many different features. It supports 4 quadrant operations easily. The drives in the series feature simplified programming by using a parameter table that provides easier data entry to enter the engineering units. The 1336 series drives feature extensive diagnostic options with both logic boards and power sources. These features run throughout the entire operation process and they relay the running information of the drives.

The 1336 FORCE drives use a time-stamped non-volatile fault warning queue to alert the operators for different system events. The drives feature a real-time clock and reference time stamps are available in the drive. The 1336 FORCE drives are manufactured with enclosed constructions and they can be used in extreme and harsh environments. The drives in this series feature different types of encoder feedback options. They come with incremental and dual-channel encoders. The drives provide speed regulation by using the feedback devices. The 1336 series provides torque regulation up to +/-5% of the rated motor torque. The current limit of these drives can be programmed from 200% of the rated output current.