Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 PLUS Drives Repair

Allen Bradley 1336 PLUS Drives Repair

We offer extensive repairs for your 1336 PLUS Drives. We keep many spare parts in stock so that we can repair your 1336 PLUS Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 PLUS Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 PLUS Drives parts.

Browse 1336 PLUS Drives Repairs

Browse our catalog of repairable 1336 PLUS Drives parts to get a quote.

1336S-A007-AN-ES4

This drive operates at a voltage of 200 to 240 volts AC with a 3-phase input. Its frequency ranges from 48 to 62 Hertz and can handle output frequencies up to 400 Hertz. The unit has an IP00 degree of

In Stock Ships Tomorrow

1336S-A007-AN-L4

Engineered for flexibility, this drive operates in a three-phase system with input voltages of 200-240 V AC and a DC input of 310 V. It features a rated current capability of 27 A and has an IP20 prot

In Stock Ships Tomorrow

1336S-A010-AA-EN

With a continuous output current of 27 A, this drive supports a robust overload capacity of 150% for up to 60 seconds. It features an enclosure type rated at IP20, and effective forced air cooling is

Available

1336S-A010-AA-EN-HA1-L6

This AC drive features an NEMA 1 enclosure with an IP20 rating, making it suitable for indoor use. It supports a control interface rated at 115V AC and is programmed in English. The device offers sens

Available

1336S-A010-AA-EN-HA2-L6

With an operational voltage range set between 200 and 240 volts AC, this drive offers a maximum output frequency capability of 400 Hz. It’s designed for vertical installation, featuring an NEMA 1 encl

Available

1336S-A010-AA-EN-L4

This adjustable frequency drive operates at ratings of 200 to 240 volts AC and delivers a maximum horsepower of 10 HP. The unit features an IP20 rating, suitable for indoor use, and includes a NEMA 1

Available

1336S-A010-AA-EN-L5

This adjustable frequency AC drive operates at rated voltages between 200 and 240 VAC, providing consistent performance for motor control. It has a nominal capacity of 10 HP and is rated IP20, indicat

Available

1336S-A010-AA-EN4-HA1-L6

This adjustable frequency AC drive operates at an input frequency of 48 to 62 Hz, providing an output frequency range of 0 to 400 Hz. The unit features an IP 20 (NEMA 1) enclosure and a control interf

Available

1336S-A010-AA-EN4-L6

This drive supports a 3-phase input configuration and handles 35 A of current under constant torque conditions. With an overload capacity reaching 150% for up to 60 seconds, it can deliver robust perf

Available

1336S-A010-AA-EN5-L6

This adjustable frequency AC drive features an IP20 rating for ingress protection and is housed in a NEMA 1 enclosure. It comes equipped with a 115V AC control interface and supports temperatures from

Available
Showing 11-20 of 1,033 results

About 1336 PLUS Drives

The 1336 PLUS drive series is a series of adjustable frequency drives by Allen-Bradley/Rockwell Automation. These drives feature voltage ratings of 200 to 240 Volts AC, 380 to 480 Volts AC, or 500 to 600 Volts AC, with an output frequency range of 0 to 400 Hertz. Additionally, this series of drives has a wide range of enclosures including the IP 00 Open, Enclosed IP 54 NEMA Type 12, Enclosed IP 20 NEMA Type 1, or Enclosed IP 65 NEMA Type 4. Generally, the 1336 PLUS drives are ideal for direct connection to the AC line with the right input power. Nevertheless, there are conditions where it might be ideal to add an isolation transformer or line reactor to the drive. There are many acceptable cable options for the installation of these drives. In most cases, installation with unshielded cable is recommended as long as it can be detached from the sensitive circuits.

The start and stop control circuits of the 1336 PLUS drives include solid-state elements. When there is a danger of the drives having accidental contact with moving machinery or unplanned liquid spills, solid debris, or gas, the drives might need extra hardwired stop circuits to help to get rid of the AC line power to this drive. When the AC power is removed, the inherent regenerative braking effect will be lost, and the motors will eventually stop, which leads to the need for an auxiliary braking method. Furthermore, the immunity of 1336 PLUS drives to the interference generated externally is superb. Typically, there are no unique precautions necessary for these drives beyond the usual installation practices required by the manufacturer. The suppression of the coils of the DC-energized contactors that are linked with the drives is highly recommended because they can lead to more serious electrical transients which can damage the drives.