Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 PLUS Drives Repair

Allen Bradley 1336 PLUS Drives Repair

We offer extensive repairs for your 1336 PLUS Drives. We keep many spare parts in stock so that we can repair your 1336 PLUS Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 PLUS Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 PLUS Drives parts.

Browse 1336 PLUS Drives Repairs

Browse our catalog of repairable 1336 PLUS Drives parts to get a quote.

1336S-B020-AN-EN-HA1

This drive accommodates input voltages from 380 to 480 volts AC and functions efficiently across a frequency range of 50 to 60 Hz. In constant torque scenarios, the input kVA ranges between 21 and 26,

Available

1336S-B020-AN-EN-L6

This adjustable frequency AC drive is rated for 15 kW and operates within a voltage range of 380 to 480 VAC. It also permits installation at altitudes up to 1000 meters. The unit supports a control in

Available

1336S-B020-AN-EN3

This drive features an open type enclosure and has an IP rating of IP00, indicating suitability for indoor, dry settings without ingress protection against dust or liquids. Its operation is effective

Available

1336S-B020-AN-EN3-GM1-HA1

Operating on voltages ranging between 380 and 480 VAC, this unit has a power output of 15 kW. The enclosed design is categorized as open type, providing accessibility for various applications. It supp

Available

1336S-B020-AN-EN3-GM1-HA1-L6

This adjustable frequency AC drive offers communication capabilities through a 1-Point Remote I/O. The enclosure is rated IP00 and features an open type construction. Rated for use in environments wit

Available

1336S-B020-AN-EN3-HA1-L6

This open-type drive features an IP00 protection rating. It is capable of outputting frequencies between 0 to 400 Hz, regulating voltage from 0 up to the line voltage. The module operates effectively

Available

1336S-B020-AN-EN3-L6

This unit falls under the 1336 PLUS Drives series and operates efficiently across a 3-phase input setup. The drive features an open-type enclosure rated at IP00, and supports a control interface using

Available

1336S-B020-AN-EN4

This device features an open type enclosure and has an IP00 protection rating, making it best suited for indoor environments. The drive is designed for operation in English and supports storage and op

In Stock Ships Today

1336S-B020-AN-EN4-GM2-HA1

This adjustable frequency drive operates within a temperature range from 0 °C to 50 °C and can endure storage temperatures of -40 °C to 70 °C. It is designed to be installed at elevations up to 1000 m

Available

1336S-B020-AN-EN4-GM2-HA1-L4

This drive includes a human interface module that acts as both a programmer and controller, featuring an analog potentiometer for ease of use. The communication capabilities comprise RS-232/422/485 as

Available
Showing 351-360 of 1,157 results

About 1336 PLUS Drives

The 1336 PLUS drive series is a series of adjustable frequency drives by Allen-Bradley/Rockwell Automation. These drives feature voltage ratings of 200 to 240 Volts AC, 380 to 480 Volts AC, or 500 to 600 Volts AC, with an output frequency range of 0 to 400 Hertz. Additionally, this series of drives has a wide range of enclosures including the IP 00 Open, Enclosed IP 54 NEMA Type 12, Enclosed IP 20 NEMA Type 1, or Enclosed IP 65 NEMA Type 4. Generally, the 1336 PLUS drives are ideal for direct connection to the AC line with the right input power. Nevertheless, there are conditions where it might be ideal to add an isolation transformer or line reactor to the drive. There are many acceptable cable options for the installation of these drives. In most cases, installation with unshielded cable is recommended as long as it can be detached from the sensitive circuits.

The start and stop control circuits of the 1336 PLUS drives include solid-state elements. When there is a danger of the drives having accidental contact with moving machinery or unplanned liquid spills, solid debris, or gas, the drives might need extra hardwired stop circuits to help to get rid of the AC line power to this drive. When the AC power is removed, the inherent regenerative braking effect will be lost, and the motors will eventually stop, which leads to the need for an auxiliary braking method. Furthermore, the immunity of 1336 PLUS drives to the interference generated externally is superb. Typically, there are no unique precautions necessary for these drives beyond the usual installation practices required by the manufacturer. The suppression of the coils of the DC-energized contactors that are linked with the drives is highly recommended because they can lead to more serious electrical transients which can damage the drives.