Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 PLUS Drives Repair

Allen Bradley 1336 PLUS Drives Repair

We offer extensive repairs for your 1336 PLUS Drives. We keep many spare parts in stock so that we can repair your 1336 PLUS Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 PLUS Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 PLUS Drives parts.

Browse 1336 PLUS Drives Repairs

Browse our catalog of repairable 1336 PLUS Drives parts to get a quote.

1336S-BX060-AN-EN-L6

This adjustable frequency drive operates within an input frequency of 50/60 Hz and provides an output frequency range of up to 400 Hz. It features an open enclosure type rated at IP00 and supports a 3

In Stock Ships Today

1336S-BX060-AN-EN3

The 1336S-BX060-AN-EN3 drive is made by Allen-Bradley/Rockwell Automation and it is part of their 1336 PLUS product series. This industrial component has an output power rating and 45 killowatts or 60

In Stock Ships Today

1336S-BX060-AN-EN3-HA1-L5

Specifically set for operational temperatures ranging from 0 to 50°C, this drive can be stored under varying conditions, from -40°C to 70°C. With a relative humidity tolerance of 5 to 95%, it is suita

In Stock Ships Today

1336S-BX060-AN-EN4

Operating effectively between temperatures of 0 degrees Celsius and 50 degrees Celsius, the drive is suitable for a range of industrial environments. The enclosure type is open, with an IP protection

In Stock Ships Today

1336S-BX060-AN-EN5

This drive supports both constant torque and variable torque operation, managing input and output currents of 75 Amps and 77 Amps, respectively. It employs standard Volts/Hertz control and sensorless

In Stock Ships Today

1336S-BX060-AN-EN5-HA2

This adjustable frequency drive is rated at 45 kW with an IP00 protection level, which means it is open type with no special environmental protections. It features an operating temperature range of 0

In Stock Ships Today

1336S-BX060-AN-EN6

This adjustable frequency drive operates effectively at a rated voltage of 460 VAC and can handle temperatures between 0 °C and 50 °C during operation. It is suitable for use in environments with rela

In Stock Ships Today

1336S-BX060-AN-FR4

This adjustable frequency AC drive operates with a notable power rating of 45 kW. With a temperature operating range from 0°C to 40°C and storage capabilities spanning -40°C to 70°C, it is designed fo

In Stock Ships Today

1336S-C007-AA-EN

Designed within an IP20-rated enclosure of NEMA Type 1, this drive operates at voltages ranging from 500 to 600 VAC. It is rated for 5.5 kW of power and is equipped with features that support an opera

Available

1336S-C007-AA-EN-HA2-L6

Designed with an IP20 protection rating, this model features a NEMA 1 enclosure. The unit can function at altitudes up to 1000 meters and maintains reliable performance in operating temperatures from

Available
Showing 931-940 of 1,033 results

About 1336 PLUS Drives

The 1336 PLUS drive series is a series of adjustable frequency drives by Allen-Bradley/Rockwell Automation. These drives feature voltage ratings of 200 to 240 Volts AC, 380 to 480 Volts AC, or 500 to 600 Volts AC, with an output frequency range of 0 to 400 Hertz. Additionally, this series of drives has a wide range of enclosures including the IP 00 Open, Enclosed IP 54 NEMA Type 12, Enclosed IP 20 NEMA Type 1, or Enclosed IP 65 NEMA Type 4. Generally, the 1336 PLUS drives are ideal for direct connection to the AC line with the right input power. Nevertheless, there are conditions where it might be ideal to add an isolation transformer or line reactor to the drive. There are many acceptable cable options for the installation of these drives. In most cases, installation with unshielded cable is recommended as long as it can be detached from the sensitive circuits.

The start and stop control circuits of the 1336 PLUS drives include solid-state elements. When there is a danger of the drives having accidental contact with moving machinery or unplanned liquid spills, solid debris, or gas, the drives might need extra hardwired stop circuits to help to get rid of the AC line power to this drive. When the AC power is removed, the inherent regenerative braking effect will be lost, and the motors will eventually stop, which leads to the need for an auxiliary braking method. Furthermore, the immunity of 1336 PLUS drives to the interference generated externally is superb. Typically, there are no unique precautions necessary for these drives beyond the usual installation practices required by the manufacturer. The suppression of the coils of the DC-energized contactors that are linked with the drives is highly recommended because they can lead to more serious electrical transients which can damage the drives.