Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 PLUS Drives Repair

Allen Bradley 1336 PLUS Drives Repair

We offer extensive repairs for your 1336 PLUS Drives. We keep many spare parts in stock so that we can repair your 1336 PLUS Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 PLUS Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 PLUS Drives parts.

Browse 1336 PLUS Drives Repairs

Browse our catalog of repairable 1336 PLUS Drives parts to get a quote.

1336S-C007-AA-EN4

Designed as part of the 1336 PLUS Drives series, this AC drive has a peak shock resistance of 15G for a maximum of 11 milliseconds. It supports operation within an ambient temperature range of 0 to 40

Available

1336S-C007-AA-EN4-HA2-L6

With an operating temperature range of 0 to 40°C, this drive accommodates different industrial conditions while storing safely from -40 to 70°C. The drive supports installation at altitudes up to 1,00

Available

1336S-C007-AA-FR

This AC drive supports a rated voltage of 500-600V AC and operates within a range of 0°C to 40°C, ensuring efficient performance. The device features an IP20 rating, denoting its open type enclosure s

Available

1336S-C007-AN-EN

This drive features a robust open-type enclosure rated at IP00. It complies with English language options and has specific trip ratings for overvoltage and undervoltage conditions. Designed to handle

Available

1336S-C007-AN-FR

Operating at 500 to 600 VAC, this drive can deliver 7.5 horsepower with a rated output current of 10 A. It functions across an input frequency range of 48 to 62 Hz and has an output frequency that can

Available

1336S-C007-AN-FR-GM1-L6

Operating between 500 and 600 VAC, this device is rated at 5.5 kW of power. It includes an open-type enclosure and is rated IP00, indicating no specific protection against dust or liquids. The drive s

Available

1336S-C007-AN-FR-L6

This AC drive features an adjustable frequency range up to 400 Hz. It includes a trip function for overvoltage conditions at 343 VAC. Its open enclosure style has an IP00 protection rating, meaning it

Available

1336S-C007-AN-FR4

This AC drive features an open enclosure rated at IP00, suitable for non-harsh environments. It provides a vertical mounting orientation and operates within a temperature range of 0 to 50 °C. This mod

Available

1336S-C007-AN-FR6

This drive supports operation in environments with temperatures from 0 °C to 50 °C. Storage capabilities extend from -40 °C to 70 °C. It operates efficiently within relative humidity levels of 5% to 9

Available

1336S-C010-AA-EN-HA1-L6

This adjustable frequency AC drive features an IP20 rating and is housed in a NEMA 1 enclosure, providing adequate protection for indoor use. With a control interface voltage of 115 VAC, it operates w

Available
Showing 941-950 of 1,033 results

About 1336 PLUS Drives

The 1336 PLUS drive series is a series of adjustable frequency drives by Allen-Bradley/Rockwell Automation. These drives feature voltage ratings of 200 to 240 Volts AC, 380 to 480 Volts AC, or 500 to 600 Volts AC, with an output frequency range of 0 to 400 Hertz. Additionally, this series of drives has a wide range of enclosures including the IP 00 Open, Enclosed IP 54 NEMA Type 12, Enclosed IP 20 NEMA Type 1, or Enclosed IP 65 NEMA Type 4. Generally, the 1336 PLUS drives are ideal for direct connection to the AC line with the right input power. Nevertheless, there are conditions where it might be ideal to add an isolation transformer or line reactor to the drive. There are many acceptable cable options for the installation of these drives. In most cases, installation with unshielded cable is recommended as long as it can be detached from the sensitive circuits.

The start and stop control circuits of the 1336 PLUS drives include solid-state elements. When there is a danger of the drives having accidental contact with moving machinery or unplanned liquid spills, solid debris, or gas, the drives might need extra hardwired stop circuits to help to get rid of the AC line power to this drive. When the AC power is removed, the inherent regenerative braking effect will be lost, and the motors will eventually stop, which leads to the need for an auxiliary braking method. Furthermore, the immunity of 1336 PLUS drives to the interference generated externally is superb. Typically, there are no unique precautions necessary for these drives beyond the usual installation practices required by the manufacturer. The suppression of the coils of the DC-energized contactors that are linked with the drives is highly recommended because they can lead to more serious electrical transients which can damage the drives.