Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 1336 PLUS Drives Repair

Allen Bradley 1336 PLUS Drives Repair

We offer extensive repairs for your 1336 PLUS Drives. We keep many spare parts in stock so that we can repair your 1336 PLUS Drives as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 1336 PLUS Drives and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 1336 PLUS Drives parts.

Browse 1336 PLUS Drives Repairs

Browse our catalog of repairable 1336 PLUS Drives parts to get a quote.

1336S-C025-AN-EN

This adjustable frequency drive is designed for operations at rated voltages between 500 and 600 V AC. With a capacity of 25 Hp, it provides reliable power management. Its IP00 open type enclosure des

In Stock Ships Today

1336S-C025-AN-EN5

This drive supports a continuous operating temperature from 0°C to 50°C and can be stored within a temperature range of -40°C to 70°C. It can be installed at altitudes of up to 1000 meters and operate

In Stock Ships Today

1336S-C025-AN-FR5

This unit operates at standard frequencies of 50/60 Hz and allows for a frequency output adjustment between 0 and 400 Hz. It utilizes a sensorless vector control method or voltage/frequency (V/Hz) tec

In Stock Ships Today

1336S-C030-AA-EN-HA2-L6

This drive operates within a voltage range of 380 to 480 VAC and provides 22 kW of power. It features a NEMA 1 enclosure rated at IP20. The operating temperature range for this model is 0 to 40 degree

Call

1336S-C030-AA-EN4-HA2-L6

This unit features an IP20 rating and complies with NEMA 1 enclosure standards. It operates effectively in a temperature range from 0 to 40°C and can be stored safely between -40 and 70°C. The device

Call

1336S-C030-AN-EN5-HA2-L6

The Allen Bradley 1336S-C030-AN-EN5-HA2-L6 drive features an open-type enclosure with an IP00 rating, suitable for indoor use. It functions optimally in ambient temperatures from 0 to 50 °C, and has s

Call

1336S-C040-AA-EN

Designed for 3-phase applications, this drive provides a minimal input voltage of 500 VAC and can handle up to 600 VAC. It features an IP20 protection rating and a NEMA 1 enclosure for non-harsh envir

Available

1336S-C040-AN-EN4

This adjustable frequency drive is designed for operation at voltages between 500 and 600 VAC. It has a rated power output of 40 horsepower and boasts an impressive efficiency of 97.50%. The device is

Available

1336S-C040-AN-FR4

This AC drive's input kVA ranges from 38 to 45 kVA for both variable and constant torque scenarios, with an input current of 44 Amps. The output capabilities remain consistent at 45 kVA, accommodating

Available

1336S-C050-AA-EN

The device features an IP20 rating and is housed in a NEMA 1 enclosure, ensuring protection against dust and solid objects. It operates effectively within a temperature range of 0°C to 40°C and suppor

Call
Showing 971-980 of 1,033 results

About 1336 PLUS Drives

The 1336 PLUS drive series is a series of adjustable frequency drives by Allen-Bradley/Rockwell Automation. These drives feature voltage ratings of 200 to 240 Volts AC, 380 to 480 Volts AC, or 500 to 600 Volts AC, with an output frequency range of 0 to 400 Hertz. Additionally, this series of drives has a wide range of enclosures including the IP 00 Open, Enclosed IP 54 NEMA Type 12, Enclosed IP 20 NEMA Type 1, or Enclosed IP 65 NEMA Type 4. Generally, the 1336 PLUS drives are ideal for direct connection to the AC line with the right input power. Nevertheless, there are conditions where it might be ideal to add an isolation transformer or line reactor to the drive. There are many acceptable cable options for the installation of these drives. In most cases, installation with unshielded cable is recommended as long as it can be detached from the sensitive circuits.

The start and stop control circuits of the 1336 PLUS drives include solid-state elements. When there is a danger of the drives having accidental contact with moving machinery or unplanned liquid spills, solid debris, or gas, the drives might need extra hardwired stop circuits to help to get rid of the AC line power to this drive. When the AC power is removed, the inherent regenerative braking effect will be lost, and the motors will eventually stop, which leads to the need for an auxiliary braking method. Furthermore, the immunity of 1336 PLUS drives to the interference generated externally is superb. Typically, there are no unique precautions necessary for these drives beyond the usual installation practices required by the manufacturer. The suppression of the coils of the DC-energized contactors that are linked with the drives is highly recommended because they can lead to more serious electrical transients which can damage the drives.