Free UPS Ground on All Orders!
+1 (919) 205-4392
Allen Bradley 140G MCB Repair

Allen Bradley 140G MCB Repair

We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-H0C4-C35

Designed as part of the 140G series, the 140G-H0C4-C35 model features a frame size categorized under H. This circuit breaker includes four poles and accommodates a current range of up to 35 A. It offe

Call

140G-H0C4-C40

The 140G-H0C4-C40 serves as a four-pole, molded case circuit breaker with a specified current range of 40 Amps. It provides both fixed thermal and fixed magnetic protection types, with a rated insulat

Call

140G-H0C4-C50

This model features a robust H frame design and is equipped with four poles. The unit operates within a current range of 50 Amps and is designed for insulation voltages rated at 1000 V. It also has an

Call

140G-H0C4-C60

As part of the 140G MCB series, the 140G-H0C4-C60 is engineered with fixed thermal and fixed magnetic protections. It encompasses four poles and has a current handling capability of 60 A. This circuit

Call

140G-H0C4-C63

This molded case circuit breaker, designated 140G-H0C4-C63, features an H frame structure. It is capable of handling a continuous current of 125 Amps with a notable interrupting capacity of 100 kA. De

Call

140G-H0C4-C70

The 140G-H0C4-C70 circuit breaker features four poles and operates within a current range of 70 Amps. It has a high interrupting rating of 100 kA, ensuring it can handle severe fault conditions. It is

Call

140G-H0F3-C90

This circuit breaker operates within a frame classified as H and has an adjustable thermal and magnetic protection feature. It supports a current range of up to 90 amps and is rated for insulation vol

Call

140G-H0F3-D10

This molded case circuit breaker operates under a frame of type H and supports a current range of 100 A. The rated insulation voltage is 1000 V, with an impulse withstand voltage rated at 8 kV. The pr

Call

140G-H0F3-D11

Designed with a frame size of H, the 140G-H0F3-D11 circuit breaker can handle interruptions up to 100 kA. This unit supports a current range of 110 Amps. The insulation voltage rating is 1000 Volts, a

Call
Showing 161-170 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.