Allen Bradley 140G MCB Repair

Allen Bradley 140G MCB Repair

We offer extensive repairs for your 140G MCB. We keep many spare parts in stock so that we can repair your 140G MCB as efficiently and effectively as possible. Our standard repair lead time is 2-4 weeks. However, we can often repair your unit much faster if necessary. We can repair most issues with your 140G MCB and if for some reason we cannot repair your unit we will do our best to offer a refurbished unit at the repair cost, so that you can get a working unit back as soon as possible!

  • 2 Year DO Supply Warranty
  • Fast repairs at low costs
  • No surprises or up-charges for difficult repairs
  • Standard lead time of 2-4 weeks
  • Extensive quality control and testing
Get a repair quote
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Hardware issues & error codes we repair

We repair all of the following hardware issues and error codes with your 140G MCB parts.

Browse 140G MCB Repairs

Browse our catalog of repairable 140G MCB parts to get a quote.

140G-K0X3

This circuit breaker is built for efficient protection with breaking frame technology. It operates at a rated insulation voltage of 1000 volts and withstands impulse voltages up to 8 kV. At 7.17 pound

In Stock Ships Today

140G-K0X4

This circuit breaker operates at a maximum current of 400 amps and has a rated insulation voltage of 1000 volts. The design has a rated impulse withstand voltage of 8 kV. Weighing 9.15 pounds, this un

Call

140G-K15F3-D30

The circuit breaker operates at 300 A of rated current and features adjustable thermal and magnetic protection options. It is rated for insulation voltages of up to 1000V and can withstand impulse vol

In Stock Ships Today

140G-K15H3-D30

This circuit breaker unit is categorized with a K frame size and can operate at 300 A of rated current and 400 A of maximum current. It withstands rated insulation voltages of 1000 volts and has an im

Call

140G-K15H3-D40

This circuit breaker operates within a current range of 400 A and employs electronic LSI protection for enhanced safety. It is constructed to endure demanding environments and is rated for up to 1000

Call

140G-K15H4-D30

This molded-case circuit breaker, built with a K frame, has a rated current of 300 A and a maximum current of 400 A. It operates efficiently at an insulation voltage of 1000 volts and can withstand im

Call

140G-K15H4-D40

This circuit breaker supports a current range of 400 Amps and includes four poles. It has a rated insulation voltage of 1000 volts and withstands impulse voltages of up to 8 kV. Weighing 9.15 pounds,

Call

140G-K15I3-D40

This circuit breaker employs an electronic LSIG protection mechanism and has a frame size of K. It supports a rated insulation voltage of 1000V and can withstand impulse voltages of up to 8 kV. The un

Call

140G-K15I4-D30

This 4-pole circuit breaker is designed to operate with a rated current of 300 A. It features electronic LSIG protection and is rated for an insulation voltage of 1000 volts. It can handle impulse wit

Call
Showing 971-980 of 1,219 results

About 140G MCB

The Allen-Bradley 140G MCB series is a series of molded case circuit breakers whose usable value can be linked to absolutely all branches of industry, and they can also be implemented in buildings and homes. The 140G circuit breakers are 3-pole or 4-pole protective devices that are available with continuous current ratings between 125 and 3000 Amps. Their maximum operating voltage is 690 Volts AC. For standard electrical installations, customers usually buy circuit breakers with fixed thermal and magnetic protection options, but 140G units are also available with the adjustable thermal/fixed magnetic combination protection feature as well as with the molded case switch (isolator) options. The 140G circuit breaker housing is made of a special plastic that is a good insulator and that is not susceptible to wear and tear due to exposure to high temperatures. The mechanical construction is designed to prevent the jamming of moving parts, thus giving the devices a high level of safety in operation. The lifespan of these molded case circuit breakers is estimated to be over 25,000 mechanical operations.

The Allen-Bradley 140G molded case circuit breakers respond with lightning speed to the appearance of short-circuits, and the force separating the contacts inside of these units is proportional to the current flowing through them, so the speed of contact separation increases with the increase of the short-circuit current to which the device needs to respond. Internal options that can be factory installed on the 140G series circuit breakers are shunt trip, undervoltage release, alarm contacts, and auxiliary contacts. All the products from this series can be reverse-fed, which simplifies the installations in some applications. Allen-Bradley has certified that the 140G series circuit breakers with all their accessories meet the CE, UL, CSA, IEC, and the CCC standards.