104 results
Horner Electric / APG
This stepper positioning module has a maximum inrush power consumption of 0.38 watts. It maintains functionality in humidity levels between 5% and 95%, non-condensing. The device communicates via RS-232 or RS-485 ports and utilizes ASCII BASIC as its programming language, allowing for advanced contr
Horner Electric / APG
The HE693IBS100 operates within a temperature range from 0 to 60 °C, with storage capabilities extending from -40 to 85 °C. This module can accommodate up to 500 kHz communication speeds over the Interbus-S network. Typically, it provides 1500 VAC isolation to ensure reliable operation, while its de
Horner Electric / PLC I/O
A component of the PLC I/O series, the HE670ADC830 module consists of 8 individual channels with selectable input ranges of either 0 to 10 VDC or -10 to +10 VDC. It has an input impedance of 1 Mohm and delivers a resolution of 12-bits, allowing for precision in data measurement. The device operates
Horner Electric / RTU Master Communication Modules
This PID network module features Proportional-Integral-Derivative control for effective regulation. It can manage inputs from analog process signals and provide output in the form of analog DC, typically in the ranges of 0–10 V or 4–20 mA. The update or scan time per loop is less than 100 ms, subjec
Horner Electric / APG
This motion control module operates effectively in environments with humidity levels between 5% and 95% without condensation. It supports an encoder input frequency of up to 1.0 MHz and can output step signals at 245 kHz. The device features communication ports conforming to RS-232 and RS-485 standa
Horner Electric / PLC I/O
This DC input module operates with a low power consumption of less than 1 watt. It supports up to 16 input channels and features optical isolation for each channel to enhance protection. The response time is typically below 10 milliseconds, ensuring rapid signal processing for effective control.
Horner Electric / PLC I/O
This module is designed to handle four analog input channels, accommodating a maximum input range of +/- 10 volts. It offers a steady-state power consumption of 0.7 watts at 5 volts and 1.2 watts at 24 volts. The device's over-voltage tolerance reaches +/- 15 volts DC, along with robust channel-to-c
Horner Electric / APG
This stepper positioning module features a significant step output frequency of 245 kHz and an encoder input frequency of up to 1.0 MHz. It is programmable in ASCII BASIC, allowing for comprehensive operations utilizing an instruction set that includes floating-point calculations, logarithmic, and t
Horner Electric / PLC I/O
The HE693ADC420 is an analog input module with four channels, operating within an input range of 4 to 20 milliamperes and suitable for use in various applications. It integrates an A/D type that processes signals effectively, boasting a resolution of 18 bits, ensuring high accuracy. The module suppo
Horner Electric / PLC I/O
This isolated RTD input module enables operational measurements across six channels. It features an update rate of 12.5 channels per second, providing quick feedback for real-time monitoring. Capable of functioning in ambient environmental conditions, it operates within a temperature range of 0 to 6