254 results
Allen Bradley / PLCs / 140U MCB
The Allen-Bradley 140U-JD6D3-D15 circuit breaker features a thermal-magnetic/adjustable magnetic trip and magnetic trip range of 750 to 1500 Amps. The continuous current rating of the circuit breaker unit is 150 Amps and it features a size 4 NEMA starter. The unit comes with three poles and a JD Fra
Allen Bradley / PLCs / 140U MCB
The 140U-JTD3-D10 circuit breaker is a molded case circuit breaker that has been designed and distributed by Allen-Bradley/Rockwell Automation. The Allen-Bradley/Rockwell Automation 140U-JTD3-D10 molded case circuit breaker operates with an AC voltage of 690 Volts AC at a frequency rating of 50 Hert
Allen Bradley / PLCs / 140U MCB
The 140U-JTD3-D17 circuit breaker is an adjustable magnetic and fixed thermal circuit breaker that employs two different detection mechanisms that employ temperature sensors and magnets to detect different types of current, generally current that, due to its abnormal nature, tends to cause damage to
Allen Bradley / PLCs / 140U MCB
The 140U-I3C3-C80 circuit breaker is a Frame I molded-case circuit breaker that has been designed and developed by Allen-Bradley/Rockwell Automation. This breaker comes with a fixed-thermal and fixed-magnetic detection mechanism that consists of the use of two bimetal bars combined with magnets.
Allen Bradley / PLCs / 140U MCB
The 140U-JTD3-D20 circuit breaker is a molded-case circuit breaker that has been designed to provide protection to different equipment such as induction motors and branch circuits, and it provides electrical protection against abnormal currents that might cause severe damage to the whole circuit.
Allen Bradley / PLCs / 140U MCB
This circuit breaker supports various interruption ratings, including 35 kA at 480 Volts AC and 65 kA for both 480 Volts and 380 to 415 Volts AC. It has long-time and instantaneous trip functions and adjustable thermal settings. The magnetic trip adjustment spans from 1,500 to 3,000 amperes.
Allen Bradley / PLCs / 140U MCB
This circuit breaker is equipped with a thermal magnetic trip mechanism to safeguard against overloads. Its breaking capacity stands at 14 kA, making it capable of handling significant fault currents. The component is built for harsh environments, operating efficiently between -25°C and 60°C, with a
Allen Bradley / PLCs / 140U MCB
The 140U-J3D3-D12 Molded Case Circuit Breaker is a high-performance compact breaker from Allen-Bradley/Rockwell Automation. It has a size J frame, 3 poles, and 250 Amps of frame current rating. The rated operational voltage of the breaker is 400/480 Volts AC, the rated amperage is 125 Amps, and the
Allen Bradley / PLCs / 140U MCB
This circuit breaker features a J frame size rated at 250 A and operates with three poles. Its interruption capabilities align with IEC standards across multiple voltage ranges, supporting up to 100 kA at 230 V AC. The unit also includes options for a shunt trip and a choice between thermal-magnetic
Allen Bradley / PLCs / 140U MCB
This molded case circuit breaker features a three-pole design within a K Frame configuration. It operates reliably in ambient temperatures up to 40°C and supports storage temperatures from -40°C to 80°C. Furthermore, the breaker can handle relative humidity from 5% to 95% without condensation, and i