714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is structured with three poles and a K-frame type, essential for heavy-duty tasks. It operates at a maximum voltage of 600 VAC and 250 VDC, with interrupting capacities of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. Its trip mechanism employs fixed thermal and fixed m
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a rated current of 15 A, suitable for various applications. It has an interrupting capacity of 14 kA at 480 V and 18 kA at 240 V. Supporting frequencies of 50 to 60 Hz, this breaker is specifically designed with load side terminals.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features a thermal-magnetic trip technology and has an interrupting rating of 14 kAIC at 480 VAC. The three-pole configuration allows for three-phase operation. It has a continuous current rating of 40 A and a fixed trip setting. The frame is NEMA F-Frame with a fixed panel mounting styl
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features a single pole design and operates in a frequency range from 50 Hz to 60 Hz. The frame construction follows the FD type standard. It also accommodates terminal connections on the load side, and has an operating humidity tolerance of up to 80% (non-condensing). The trip unit is desi
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker comprises a single pole and utilizes a fixed thermal-magnetic trip unit for effective overload protection. It offers an impressive interrupting capacity of 18 kA at 240 volts AC and 14 kA at 480 volts AC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal magnetic trip unit has fixed trip characteristics for both thermal and magnetic operations. It operates effectively at frequencies of 50/60 Hz and is compatible with molded case breakers. The device is easily field replaceable, identified by the trip type code T266.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit applies to three-pole configurations, designed for utilization in a J frame. It features a fixed thermal and adjustable magnetic trip type with a magnetic trip range of 350 to 700 A. Operational frequency ranges from 50 Hz to 60 Hz, making it adaptable to different sys
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is engineered with fixed thermal and fixed magnetic trip types for dependable operation. The interrupting capacity is rated at 14 kAIC for 480Y/277 Vac and 65 kAIC at 240 Vac, suitable for handling substantial fault currents. It complies with UL certification standar
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a T186 trip type and is housed in a frame designated as Frame J. It can handle an interrupt rating of 65 kAIC at 240 Vac and 35 kAIC at 480 Vac. Weighing 9.25 lbs, this unit utilizes aluminum for its terminals and supports wire sizes ranging from 4 AWG to 350
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker trip unit has a frame size designated as Frame K and operates with a trip type T266. Designed for medium to high humidity environments, it maintains functionality in conditions up to 80% humidity. Temperature ranges for both operation and storage extend from 0°C to 4