714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed with a K frame, the KDB3350 is specified for a frequency range from 50 Hz to 60 Hz. It features line and load terminals made from aluminum. The trip type is designated as T186 and it has an interrupting capacity of 65 KAIC at 240 VAC and 35 KAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device, featuring two poles, utilizes a T186 trip type and is designed for use in various frequency settings, with a minimum frequency of 50 Hz and a maximum of 60 Hz. At an interrupt rating of 35 kAIC at 480 VAC and 65 kAIC at 240 VAC, it provides robust protection for electrical circuits.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector accommodates three poles and has a frame size classified as J-K. It operates within a magnetic trip range of 350 to 700 Amps. The device is compliant with NEMA 5 starter size and functions effectively at frequencies of 50 or 60 Hz, even in relative humidity levels up to
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a frequency of 50 to 60 Hertz and includes a thermal magnetic trip unit. Interrupt ratings are notable, with 35 kA at 277 volts AC and 10 kA at 125 volts DC. The frame type is designated as F, and it allows connections through load side pressure terminals. The device
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With support for operation at voltages of 480Y/277 VAC and 125/250 VDC, the GHB2060 is well-suited for various electrical systems. The unit has a fixed thermal and magnetic trip type and operates effectively within a frequency range of 50 to 60 Hertz. Its interrupt rating is 14 kAIC at 480Y/277 VAC
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit employs a 3-pole configuration with a feed-thru connection. The breaker carries an interrupt rating of 65 kA at 480 Volts AC, and the magnetic trip range extends from 210 to 700 Amperes. Its construction is compliant with UL and CSA standards, featuring non-aluminum terminal materials for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case breaker trip unit is compatible with breaker frames such as Type MDL, HMDL, and HMDLDC. It provides thermal magnetic protection and incorporates LI trip functions for long-time and instantaneous responses. This trip unit is designed to function effectively in temperature ranges from
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device includes a total of four auxiliary contacts, consisting of two normally open (NO) and two normally closed (NC). The switch supports a right-hand mounting orientation, operates on a single phase, and features trip indication functionality.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring three poles, this circuit breaker uses a thermal magnetic trip unit for reliable operation. It provides notable interrupt capacities of 65 kAIC at 240 volts AC, 22 kAIC at 480 volts AC, and 10 kAIC at 250 volts DC. Its design facilitates easy installation and wire connections, accommodatin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release mechanism facilitates right-hand mounting and features pigtail leads for easy installation. Its operational temperature ranges from 0°C to 40°C, while it effectively maintains performance in humidity levels of up to 80% (non-condensing). It can be installed effectively at a