714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker type is classified as EHD, featuring a 2-pole configuration. It is rated for a current of 20.0 A and a voltage range of 240 VAC to 480 VAC, along with a DC voltage rating of 250 VDC. It has interrupt ratings of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring robust performan
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for use in three-phase environments, the DOPTMLN module operates efficiently within an input voltage of 0 to 600 VAC, accommodating frequencies between 50 Hz and 60 Hz. This module includes 3 fuses rated at 600 V to ensure protection and performance. It has four terminals for secondary conn
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Compatible with 100A HMCP devices, this attachment includes three poles and accommodates wire sizes from #4 to 4/0 AWG for both copper and aluminum conductors. It requires a minimum frequency of 50 Hz and a maximum frequency of 60 Hz, making it suitable for various applications. The device incorpora
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker operates effectively within a frequency range of 50 Hz to 60 Hz. The LDC3500's interrupting capacity is rated at 65 kAIC for 240 VAC and 100 kAIC for 480 VAC. Its long-time and instantaneous trip functions ensure adequate protection under various load conditions, whil
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is rated for 600 VAC for alternating current and 250 VDC for direct current. It operates between 50 Hz and 60 Hz and has various interrupting capacities: 200 kAIC at 240V AC, 100 kAIC at 480V AC, and 50 kAIC at 600V AC. It employs thermal-magnetic trip technology with both long-
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is built with a fixed thermal-magnetic trip mechanism. Rated interrupt capacities include 100 kAIC for 240 Vac, 65 kAIC for 480 Vac, and 35 kAIC for 600 Vac. It includes terminals for line/load connections and is suitable for conductors made from either copper or aluminum.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is configured with three poles, making it suitable for 3-phase systems. It has an interrupt rating of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring reliable fault protection. The trip mechanism is thermal-magnetic, and the terminals are made of aluminum, designed for both
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and utilizes an F frame type design. Protection is provided by fixed thermal and fixed magnetic trip types. It includes lugs for both line and load terminal connections and boasts an interrupting capacity of 65 kAIC at 240 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Configured for two poles, the DK2300 offers a frequency rating of 50/60 Hz. This model features a T186 trip type and comes with aluminum terminals for line and load connections. It has an interrupt capacity of 65 kAIC at 240 Vac and 10 kAIC at 250 Vdc, ensuring effective protection for circuits. The
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a rated interrupting capacity of 65 kAIC at 240 VAC, ensuring safety during fault conditions. It features a trip mechanism using both fixed thermal and magnetic settings, suitable for various applications. It is mountable using panel mount or bolt-on methods, with a frequenc