Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

KS84621440

KS84621440

Honeywell / IFD Series

This module is capable of functioning within a temperature range of -20 °C to 60 °C. It has a weight of 1.5 lbs and supports an input voltage frequency of 50/60 Hz. With a designed lifetime of 250,000 operating cycles for the control unit and 1,000 for the reset/mains buttons, it ensures long-term r

Call
21CH38-18

21CH38-18

Honeywell / Micro Switch

This limit switch features a roller arm actuator style and a double-pole double-throw (DPDT) contact configuration. It operates within a wide temperature range, from -20°C to 105°C, and is rated for a 10.0 A current. With a NEMA rating covering 1, 3, 4, 6, 6P, 12, and 13, it is suitable for multiple

Call
060-9584-01

060-9584-01

Honeywell / Model 41 Series

Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above

Call
SPXCDULNRXM

SPXCDULNRXM

Honeywell / Sensepoint XCD

This flame detector weighs 1.05 lb and operates at a nominal voltage of 24 VDC with a current rating of 25 mA. Its IP65 rating provides protection against dust and water. The dual-sensor technology employs Ultraviolet/Infrared (UV/IR) sensing, ensuring a detection range of up to 80 ft (25 m). Its co

Call
SPXCDULNC2R

SPXCDULNC2R

Honeywell / Sensepoint XCD

This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an

Call
S301-IRF-R134A

S301-IRF-R134A

Honeywell / 301EM Series

The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.

Call
S301-IRF-R123

S301-IRF-R123

Honeywell / 301EM Series

This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid

Call
SPXCDULNRFD

SPXCDULNRFD

Honeywell / Sensepoint XCD

This gas detector functions within a voltage range of 16 to 32 VDC and operates efficiently between -40°C and +65°C. It has an IP66 rating, ensuring robust protection against dust and water ingress. Features include a current output range of 4-20 mA, capable of sinking or sourcing current and provid

Call
1226-9003

1226-9003

Honeywell / XNX Universal Transmitters

This surface-mounted unit is constructed from painted LM25 aluminum and features an LCD display for easy readability. It includes multiple digital communication options such as HART, MODBUS, and FOUNDATION H1 Fieldbus. The unit has an isolated 4-20 mA analog output for HART communication and a digit

Call
SPXCDXSRXSS

SPXCDXSRXSS

Honeywell / Sensepoint XCD

This replacement cartridge provides methane detection with a range from 0 to 100% LEL. It features a robust 316 stainless steel housing for durability and is rated IP66 for protection against dust and water. The device operates between 12 to 32 VDC and maintains function across a significant pressur

Call
Showing 121-130 of 966 results