Honeywell / 7800 Series
This device is designed for mounting as a plug-in module on Q7800A/Q7800B wiring subbases. It supports interrupted pilot types and has a main flame establishment duration of 10 seconds and a postpurge timing of 15 seconds. The operational temperature range extends from -40°C to a maximum of 60°C, ac
Honeywell / SLATE
This base module, weighing 2 lbs, operates between specified frequencies of 50 Hz and 60 Hz, making it suitable for a wide range of applications. It is built to function optimally in environments with a temperature range from -29°C to 66°C, and can be stored safely at temperatures as low as -40°C. T
Honeywell / V4055
This actuator provides a consistent opening time of 13 seconds while ensuring a fast closing time of one second or less. It operates effectively at an ambient temperature range from -23°C to 70°C and handles a pressure of 5 PSI. The NEMA 1 enclosure is rated IP30, offering a good level of protection
Honeywell / Micro Switch
The EXH-AR33 model operates at a current rating of 1.0 A and a voltage rating of 125 VAC. It has an operating force ranging from 2.22 N to 6.67 N, and a differential travel of 0.25 mm. This switch is housed in rugged aluminum and has a NEMA rating of 1, 7, and 9. Designed for extreme conditions, it
Honeywell / Sensepoint XCD
This gas detector functions within a voltage range of 16 to 32 VDC and operates efficiently between -40°C and +65°C. It has an IP66 rating, ensuring robust protection against dust and water ingress. Features include a current output range of 4-20 mA, capable of sinking or sourcing current and provid
Honeywell / XNX Universal Transmitters
This transmitter POD is compatible with EC sensors and Honeywell's Analytics range of gas sensors. It includes three SPDT relay outputs and is designed for surface mounting. The unit boasts digital communication capabilities, including HART Communications, MODBUS, and FOUNDATION H1 Fieldbus, enhanci
Honeywell / XNX Universal Transmitters
This transmitter pod is equipped with standard options and communicates using the HART protocol. It offers an analog output signal in the range of 4–20 mA. Designed for a broad environment, it functions at temperatures between -40°C and 65°C and supports humidity levels from 0% to 99% (non-condensin
Honeywell / Other
This UV flame detector weighs 6 lbs and has a robust NEMA 4 rating for environmental protection. It is effective in temperatures ranging from -40°C to 79°C, accommodating various operational situations. This device includes a self-check function where an oscillating shutter interrupts the UV signal
Honeywell / Other
This valve features a pipe size of 1-1/4 inches (DN32) and has a large flow body design, ensuring optimal performance at a maximum operating pressure of 0.5 psi (34 mbar). It can modulate from 14% to 100% of the burner load, providing precise control. Electrical connections are made via a DIN 43650