Honeywell / V8944
This valve is a rapid-opening diaphragm type, which features an impressive flow capacity ranging from 780 to 2300 CFH. It operates at a frequency of 60 Hz and consumes 12.4 VA of power. The device is constructed from die-cast aluminum and has opening and closing times of less than 6 seconds and 2 se
Honeywell / IFD Series
This module is capable of functioning within a temperature range of -20 °C to 60 °C. It has a weight of 1.5 lbs and supports an input voltage frequency of 50/60 Hz. With a designed lifetime of 250,000 operating cycles for the control unit and 1,000 for the reset/mains buttons, it ensures long-term r
Honeywell / Model 41 Series
This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat
Honeywell / Searchpoint Optima Plus
This gas detector weighs 4.4 lbs and has an IP66 rating, making it suitable for harsh conditions. The operating temperature range extends from -40°C to +65°C, which enhances its versatility. It features a current rating with a maximum inrush of 800 mA at 24VDC and consumes 3.7W of power when using t
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / 301EM Series
Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from
Honeywell / 301EM Series
This sensor is designed to detect hydrogen and other combustible gases. It connects with 301EM expansion modules or 301C controllers and can be positioned up to 500 feet away. Response time ranges from 30 to 60 seconds, and it communicates via the 301EM controller. It operates effectively in tempera
Honeywell / 301EM Series
This sensor is engineered to monitor hydrogen sulfide gas, showcasing an electrochemical sensing method for accurate measurements. It operates across a temperature range of -40°C to 40°C and can handle humidity levels between 0% and 95% non-condensing. The device includes four DPDT relays for alarm
Honeywell / Sensepoint XCD
Designed to cater specifically to carbon dioxide, this gas detector features an IP65 rated enclosure made from durable polycarbonate with a sleek charcoal finish. It operates on a power supply of 24 VDC and is equipped with a 4 to 20 mA analog signal output along with two programmable relay outputs.
Honeywell / V5055
The V5055D1032 operates under a maximum rated pressure of 75 PSI with the ability to handle a pressure differential of up to 15 PSI using a standard actuator and 45 PSI with a high-pressure actuator. It is capable of functioning in a broad ambient temperature range, from -40 °C to 66 °C, and demonst