Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / ControlEdge HC900
This control station has an operating voltage range from 10 to 30 volts and consumes up to 21 watts at 10 volts and 22 watts at 30 volts. It includes a lithium coin cell battery, providing additional support. The unit is rated for an operating temperature between -10 °C and 50 °C.
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio
Honeywell / SmartLine
This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int
Honeywell / SmartLine
This gauge pressure transmitter utilizes piezoresistive sensor technology for precise measurements. It is designed to handle pressure ranges from -14.7 in H2O to 500 in H2O. The device has a robust weight of 8.3 lbs and features a dual-ended head. It is made with durable materials such as plated car
Honeywell / HercuLine 2001
This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35