969 results
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating
Honeywell / Sensepoint XCD
This unit is rated IP66, allowing it to function effectively in harsh environments. The device operates within a temperature range of -40°C to 65°C and has a housing made of epoxy-painted LM25 aluminum alloy, ensuring durability. A maximum inrush current is specified at 800 mA at 24 VDC, with a 4-20
Honeywell / Other
Operating with two pipes, this humidistat features a throttling range from 3 to 15% RH. It consumes airflow at a rate of 0.011 scfm and maintains functionality under an operating pressure of 25 Psi. Its design allows it to work effectively across a temperature spectrum of 7 °C to 52 °C for operation
Honeywell / Other
The RP7517B1024 transducer ensures an output pressure range from 3 to 15 psi and can withstand maximum operating pressure of 30 psi. Rated for power consumption at 1.7 VA, it features a direct acting mechanism and uses screw terminals or lead wires for electrical connections. With operational temper
Honeywell / Other
This diaphragm gas valve boasts a 2-inch NPT pipe connection and is made from durable cast aluminum. It operates at an input voltage of 120 VAC and a frequency of 60 Hz. The opening and closing timing of this valve is 5 seconds and 2 seconds, respectively, and it operates safely at 1 PSI. A bleed ta
Honeywell / Other
This industrial gas valve is adaptable to various pipe sizes from 3/4 inches to 2 inches and features threads compatible with either NPT or BSP types. With an operating temperature range from -40 °C to 66 °C, this valve accommodates diverse environmental conditions, maintaining safe operation up to
Honeywell / Other
This solenoid valve is rated for operation between -20 °C and 60 °C, making it suitable for various environments. It features a black solenoid actuator paired with an aluminum valve body. The unit supports a size 2 valve and has a proof of closure switch that provides visual position feedback.
Honeywell / Other
This ionization pilot burner supports a max gas inlet pressure of 20-45 mbar and an air inlet pressure of 30-70 mbar. It produces a flame approximately 4 cm long and utilizes a direct spark ignition system with a 5kV ignition transformer. The flame is controlled through a single-electrode ionization