Honeywell / IFD Series
This module is capable of functioning within a temperature range of -20 °C to 60 °C. It has a weight of 1.5 lbs and supports an input voltage frequency of 50/60 Hz. With a designed lifetime of 250,000 operating cycles for the control unit and 1,000 for the reset/mains buttons, it ensures long-term r
Honeywell / Micro Switch
This enclosed limit switch features a 2-pole configuration and a current rating of 10.0 A. It operates at a rated voltage of 250 VAC for alternating current and 250 VDC for direct current. The actuator is designed with a side rotary lever and is suitable for chassis or screw mounting, adapting for v
Honeywell / Model 41 Series
This model features an excitation voltage of 10V DC and operates effectively in a temperature range from -54°C to 121°C. It is designed for both tension and compression operations and uses a durable housing made of 17-4PH stainless steel. The load cell accommodates a maximum relative humidity of 80%
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / Model 41 Series
This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s
Honeywell / Searchpoint Optima Plus
With a measurement range extending from 0 to 1000 ppm and a resolution of 1 ppm, this sensor provides detailed detection capability. It is built to operate efficiently within a temperature range of 0°C to 40°C and can function in humidity levels of 0-95% RH without condensation. This unit can be ins
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid
Honeywell / Sensepoint XCD
This detector features an IP66 rating, signifying its resilience against dust and water ingress. It operates efficiently in temperatures ranging from -40°C to 65°C and can be stored within a similar temperature range. Supporting humidity levels from 20-90% RH continuously, it also accommodates inter
Honeywell / Sensepoint XCD
The SPXCDULNTXF model features robust specifications, including an IP66 enclosure rating and a wide operating temperature span of -40°C to +65°C. This device accommodates continuous humidity levels between 20% and 90% RH and intermittent levels of 10% to 99% RH without condensation. Equipped with re
Honeywell / 301EM Series
This sensor is designed to detect hydrogen and other combustible gases. It connects with 301EM expansion modules or 301C controllers and can be positioned up to 500 feet away. Response time ranges from 30 to 60 seconds, and it communicates via the 301EM controller. It operates effectively in tempera