966 results
Honeywell / Micro Switch
The EXH-AR33 model operates at a current rating of 1.0 A and a voltage rating of 125 VAC. It has an operating force ranging from 2.22 N to 6.67 N, and a differential travel of 0.25 mm. This switch is housed in rugged aluminum and has a NEMA rating of 1, 7, and 9. Designed for extreme conditions, it
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / 301EM Series
This infrared gas detector efficiently measures hydrocarbons with a range of 0-100% LEL. It features an IP66/IP67 rating for dust and water resistance, operates within an extensive temperature range of -40°C to +65°C, and offers a signal output of 4-20 mA that auto-senses whether to sink or source.
Honeywell / Searchpoint Optima Plus
This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio
Honeywell / Model 41 Series
This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.
Honeywell / 301EM Series
This refrigerant gas sensor supports a voltage rating from 8.5 to 12.5 Vdc and operates with a maximum current of 1 A at 10 Vdc. It features an accuracy of ±10 ppm at low concentrations and ±40 ppm at higher levels. The operational environment accommodates temperatures between 0°C and 40°C with a hu