969 results
Honeywell / 7800 Series
The RM7895E1002 control module can establish pilot flames with timing options of either 15 or 30 seconds. The device features nonvolatile memory and allows for selectable interlocks. It operates within a temperature range from -40°C to 60°C and can withstand humidity levels up to 85% without condens
Honeywell / 7800 Series
This rectification flame signal amplifier is available in a green color code, with a flame failure response time of either 2 or 3 seconds. It provides an output voltage of 0 to 5.0V DC and is capable of resisting vibrations up to 0.5 G. The device can function at temperatures ranging from -40°C to 6
Honeywell / IFD Series
This module is capable of functioning within a temperature range of -20 °C to 60 °C. It has a weight of 1.5 lbs and supports an input voltage frequency of 50/60 Hz. With a designed lifetime of 250,000 operating cycles for the control unit and 1,000 for the reset/mains buttons, it ensures long-term r
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / Model 41 Series
This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s
Honeywell / Searchpoint Optima Plus
With a measurement range extending from 0 to 1000 ppm and a resolution of 1 ppm, this sensor provides detailed detection capability. It is built to operate efficiently within a temperature range of 0°C to 40°C and can function in humidity levels of 0-95% RH without condensation. This unit can be ins
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid
Honeywell / XNX Universal Transmitters
This gas detector operates efficiently within an extensive temperature range, from -40°C to 65°C. It can withstand storage temperatures from -40°C to 75°C and supports humidity levels of 0-99% RH, non-condensing. The housing is made of painted marine-grade LM25 aluminum alloy, ensuring durability in
Honeywell / Sensepoint XCD
The SPXCDULNTXF model features robust specifications, including an IP66 enclosure rating and a wide operating temperature span of -40°C to +65°C. This device accommodates continuous humidity levels between 20% and 90% RH and intermittent levels of 10% to 99% RH without condensation. Equipped with re
Honeywell / 301EM Series
This sensor is engineered to monitor hydrogen sulfide gas, showcasing an electrochemical sensing method for accurate measurements. It operates across a temperature range of -40°C to 40°C and can handle humidity levels between 0% and 95% non-condensing. The device includes four DPDT relays for alarm