967 results
Honeywell / Model 41 Series
Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above
Honeywell / Model 41 Series
This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s
Honeywell / 301EM Series
Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from
Honeywell / Sensepoint XCD
This unit is rated IP66, allowing it to function effectively in harsh environments. The device operates within a temperature range of -40°C to 65°C and has a housing made of epoxy-painted LM25 aluminum alloy, ensuring durability. A maximum inrush current is specified at 800 mA at 24 VDC, with a 4-20
Honeywell / Other
This display supports applications designed for control, data visibility, and monitoring. It is applicable up to an altitude of 1000 meters, with humidity tolerance up to 80% without condensation. Storage and operational temperature ranges are both compatible with 0 to 50 degrees Celsius for effecti
Honeywell / Other
This valve features a pipe size of 1-1/4 inches (DN32) and has a large flow body design, ensuring optimal performance at a maximum operating pressure of 0.5 psi (34 mbar). It can modulate from 14% to 100% of the burner load, providing precise control. Electrical connections are made via a DIN 43650
Honeywell / Other
This solenoid gas valve is suited for a pipe size of 2 inches and is made with a die-cast aluminum body for durability. The maximum operating pressure is rated at 5 psi (350 mbar). It has a quick response time with both opening and closing under one second. Temperature ranges from -40 °C to 63 °C ar
Honeywell / Other
This module features a two-row by twenty-column vacuum fluorescent display (VFD) and utilizes the Modbus communication protocol. Designed for robust performance, it can handle power dissipation up to 7 watts and a maximum power consumption of 2 VA. Operating temperatures range from -40 °C to 60 °C,
Honeywell / Other
This module subrack features nine available slots and weighs 5.2 lbs. It conforms to a 19" mounting standard, with construction that includes a backplane PCB and guide rails for easy installation. With a front protection rating of IP20, this subrack is optimal for use in environments with a maximum