966 results
Honeywell / Other
This burner operates at gas inlet pressures between 35 and 80 mbar and air inlet pressures from 30 to 80 mbar. The length of the flame produced is approximately 4 cm, controlled by a single-electrode ionization flame rod. It features direct spark ignition powered by a 5 kV ignition transformer, ensu
Honeywell / Other
This ionization pilot burner supports a max gas inlet pressure of 20-45 mbar and an air inlet pressure of 30-70 mbar. It produces a flame approximately 4 cm long and utilizes a direct spark ignition system with a 5kV ignition transformer. The flame is controlled through a single-electrode ionization
Honeywell / Other
This UV flame sensor has an operating and storage temperature range extending from -40°C to 80°C, allowing it to function under extreme conditions. Installation is limited to altitudes below 2000 meters above mean sea level. Its aluminum housing features an integrated heat guard, enhancing durabilit
Honeywell / Other
This controller maintains an operating temperature range from -20°C to 50°C and can handle ambient humidity levels from 0% to 95% RH without condensation. It can support three RS-485 channels and connect up to 96 transmitter inputs. Communication options include Modbus RS-485 and optional BACnet/IP,
Honeywell / Other
This refrigerant sensor is adaptable for continuous monitoring across multiple applications, including chiller plants, cold storage facilities, and food processing environments. It can function effectively at a maximum relative humidity of 80% without condensation and at altitudes up to 1000 meters.
Honeywell / Other
This device weighs 1.06 lbs and is built to perform in temperatures from -20°C to 40°C, with humidity levels acceptable from 20% to 90% RH. It provides a 4-20 mA analog output signal and is equipped with a backlit 122 x 32 dot display along with a green status LED. A six-function touch-sensitive key
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
This load cell exhibits a non-linearity accuracy of ±0.1% of full scale and a hysteresis of ±0.08%. It operates effectively within a temperature range of -54°C to 121°C, with temperature compensation guaranteed between 15°C and 71°C. The output signal is non-amplified, providing 3 mV/V ±0.5% FS, sui
Honeywell / Other
This calibration kit features a calibration adapter, hose, and regulator, facilitating the setup for gas detection systems. It supports cylinder volumes of 58 L and 103 L and is compatible with various detectors including those for ammonia, carbon monoxide, chlorine, hydrogen, nitrogen dioxide, oxyg