Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating at a frequency of 50/60 Hz, this breaker features a fixed thermal-magnetic trip unit and has an interrupting rating of 65 kA at 240V AC. With three poles and the ability to accommodate shunt trip and auxiliary switch devices, it is versatile and suitable for different installations. The de
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features K frame construction and accommodates 3 AWG to 350 kcmil wire sizes. It provides effective long-time overload protection coupled with instantaneous short-circuit protection, ensuring reliable service.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This switch comes with three poles and a K Frame type designation, allowing for versatile installations. It features high instantaneous magnetic override for self-protection and maintains a maximum interrupting capacity of 65 kA at 240 Volts and 35 kA at 480 Volts. The operating temperature range is
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip mechanism and consists of three poles, accommodating different electrical setups. It offers impressive interrupt ratings of 100 KAIC at 480 V and 200 KAIC at 240 V. Suitable for use at frequencies ranging from 50 to 60 Hz, it fits within the F frame category
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This product features two poles and is characterized by a fixed thermal-magnetic trip unit. It possesses a high interrupting capacity, capable of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. Designed for 50/60 Hz operation, it is suitable for mounting on a panelboard and utilizes a bolt-on connection
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit features three poles and mounts internally on a breaker, specifically designed for J frame compatibility. It has a non-interchangeable mounting style and provides an instantaneous trip range of 5-10 times the rated current. The unit is rated for system frequencies of 50/60 Hz and cali
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker features a J Frame and utilizes a T186 trip type. It has an impressive interrupt rating of 65 kAIC for voltages at 240 VAC and is rated for a minimum frequency of 60 Hz. The unit is suitable for use at installation altitudes up to 1000 meters above sea level, with a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This Series C circuit breaker has a current rating of 25 A and is suitable for use at voltages of 480Y/277 VAC, along with 125/250 VDC. The GHB2025 is designed to be connected using a bolt-on method and functions effectively within a frequency range of 50 to 60 Hz. With UL approval, the breaker exhi
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designated for motor protection, this circuit breaker features a magnetic trip range of 9 to 30 Amps. It is constructed with a J-K frame and incorporates non-aluminum terminal materials, enhancing durability. Certified by UL and CSA, it operates effectively at temperatures between 0 to 40 degrees Ce
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device operates with three poles and features an F frame construction, making it suitable for diverse operational requirements. Its trip mechanism is classified as T186 and it supports both line and load terminal types. Notably, the device can interrupt circuits with ratings of 18 kAIC at 240 V