Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug supports a voltage rating of 600 VAC and operates on frequencies of 50 and 60 Hz. It employs solid-state trip technology and is compatible with electronic trip units like Digitrip, RMS310, and LES. The 6LES300T features plug-in installation for easy integration and is UL Listed for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and has a weight of 4.5 lbs. It is designed for bolt-on mounting and connects via load terminals. The interrupt ratings reach 200 kAIC at 240 VAC and 100 kAIC at 480 VAC. The trip mechanism is based on fixed thermal and fixed magnetic types, which provide so
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal magnetic trip unit has fixed trip characteristics for both thermal and magnetic operations. It operates effectively at frequencies of 50/60 Hz and is compatible with molded case breakers. The device is easily field replaceable, identified by the trip type code T266.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker comprises a single pole and utilizes a fixed thermal-magnetic trip unit for effective overload protection. It offers an impressive interrupting capacity of 18 kA at 240 volts AC and 14 kA at 480 volts AC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a rated current of 15 A, suitable for various applications. It has an interrupting capacity of 14 kA at 480 V and 18 kA at 240 V. Supporting frequencies of 50 to 60 Hz, this breaker is specifically designed with load side terminals.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker encompasses three poles and is fitted with an F frame. It possesses an interrupting capacity of 65 kAIC at 240 Vac and 35 kAIC at 480 Vac. The device is suitable for frequencies between 50 and 60 Hz and includes terminal connections for both line and load, accommodating wire siz
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is engineered with fixed thermal and fixed magnetic trip types for dependable operation. The interrupting capacity is rated at 14 kAIC for 480Y/277 Vac and 65 kAIC at 240 Vac, suitable for handling substantial fault currents. It complies with UL certification standar
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating at a frequency of 50/60 Hz, this breaker features a fixed thermal-magnetic trip unit and has an interrupting rating of 65 kA at 240V AC. With three poles and the ability to accommodate shunt trip and auxiliary switch devices, it is versatile and suitable for different installations. The de
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for three-phase systems, this model has three poles and is capable of handling significant fault currents, with interrupting ratings of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. The device operates efficiently within a frequency range of 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This breaker frame features a total of three poles. It operates efficiently within a frequency range of 50 to 60 Hz. It boasts significant interrupting capacities: rated at 100 kAIC for 240 VAC, 65 kAIC for 480 VAC, and 35 kAIC for 600 VAC, providing effective protection in various electrical applic