197 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker possesses a fixed thermal and fixed magnetic trip system and is configured with three poles. With a robust interrupting capacity of 65 kAIC at 480 Vac, 35 kAIC at 600Y/347 Vac, and 100 kAIC at 240 Vac, it is designed for reliable operation. The frame is categorized as EG, suppor
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This molded case circuit breaker operates efficiently in a frequency range of 50 to 60 Hz. Its impressive interrupt ratings stand at 65 KAIC at 480 VAC and 125 KAIC at 240 VAC, ensuring effective protection in various fault scenarios. The rated voltage is capped at 600 V, and it can be installed at
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This model includes three poles and operates within a frequency range of 50 to 60 Hz. It utilizes a T186 trip type for dependable protection and is housed in an EG frame. It has significant interrupt ratings of 85 KAIC at 240 VAC and 35 KAIC at 480 VAC, ensuring safety during fault conditions.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker is part of the Series G family and features an LG-frame design, weighing 16 lbs. It operates with three poles and three wires, ensuring effective circuit protection in various applications. The breaker provides significant interrupting capacity at different voltages, with 65 kAI
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
The NGFCT080 is designed with an N frame type and can function within a temperature range of 0°C to 40°C. It maintains an 80% non-condensing humidity resistance for both operating and storage conditions. Installed at altitudes up to 1000 MSL, it is suitable for various environments.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This mini circuit breaker operates within a voltage rating of 600Y/347 VAC. The device supports fixed thermal and magnetic trip types and offers interrupting ratings of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600Y/347 VAC. It's designed for a frequency range of 50 to 60 Hz and featur
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker has three poles and utilizes a thermal magnetic protection scheme. It is intended for DIN rail mounting and connects via bolt-on lugs, with a load side terminal. Suitable for installation at altitudes up to 1000 MSL, it offers long-time and instantaneous trip functions.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features a JG frame type and consists of three poles. The interrupt ratings are significant, reaching 65 kAIC at 240 VAC, 25 kAIC at 480 VAC, and 18 kAIC at 600 VAC. It supports a maximum operating frequency of 60 Hz and a minimum of 50 Hz, making it versatile for different oper
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This accessory operates at a maximum voltage of 600 Y/347 volts and utilizes a magnetic trip range of 9-30 amps. It features connections that are bolted for both line and load, and it has an approved frame size labeled J-K. Constructed with thermoset and thermoplastic materials, it is compliant with
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
The EGH3025FFG circuit breaker operates at a minimum frequency of 50 Hz and a maximum of 60 Hz, ensuring compatibility across various systems. With a trip type defined as T186, it delivers reliable performance under diverse electrical conditions and provides significant interrupt ratings with 100 KA