Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This shunt trip operates in a 3-phase input configuration and is suitable for left-hand mounting, featuring dual connection with pigtail leads. It is capable of handling a maximum current rating of up to 2,500 amperes. This unit has a solid amperage capacity of 225 amperes and functions effectively
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory features LSIG trip functions, providing long-time, short-time, instantaneous, and ground fault protection. It operates at a rated voltage of 600 VAC and covers frequency parameters between 50 Hz and 60 Hz. This model is equipped with true RMS sensing for accurate readings and utilizes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a compact F frame design, this device includes two poles and is rated for an impressive 150 Amps. It accommodates a frequency range between 50 Hz and 60 Hz. The circuit breaker is equipped with high interrupting capabilities, rated at 100 KAIC for 240 VAC and 65 KAIC for 480 VAC, ensuring
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type and is constructed with a Frame G size. Designed with two poles, it is compatible with a frequency range of 50 to 60 Hz. The interrupting capacity is rated at 65 KAIC for 240 VAC and 14 KAIC for 480Y/277 VAC, providing reliable protection against electr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed with a K frame, the KDB3350 is specified for a frequency range from 50 Hz to 60 Hz. It features line and load terminals made from aluminum. The trip type is designated as T186 and it has an interrupting capacity of 65 KAIC at 240 VAC and 35 KAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for single-pole applications, this field-mounted undervoltage release operates efficiently within a frequency range of 50 to 60 Hz. The connection type is pigtail lead, and the unit is certified by UL, which is indicative of its adherence to established safety standards.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This two-pole circuit breaker utilizes a T186 trip type and offers a frame classified as F. It supports frequency ranges from 50 Hz to 60 Hz. For fault protection, the FDB2025 has an interrupt rating of 14 kAIC at 480 V and 18 kAIC at 240 V.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type, combining fixed thermal and magnetic functions. It is configured with three poles and facilitates a line and load terminal arrangement, using aluminum for terminal construction. The J frame design supports frequency ratings from 50 Hz to 60 Hz, and it
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The GHB2020 circuit breaker is rated for AC voltage levels up to 277/480 V and DC ratings of 125/250 V. With a fixed thermal-magnetic trip type, it offers reliable performance across varying conditions. Its interrupting capacity is rated at 14 kA at 277/480 V, providing essential protection against
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker is constructed from non-aluminum materials for the terminals. The HMCP015E0C is rated for a voltage of up to 600 V AC and provides instantaneous magnetic protection. It is compatible with environments featuring high humidity levels, with operating and storage humidity