Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features a thermal-magnetic trip technology and has an interrupting rating of 14 kAIC at 480 VAC. The three-pole configuration allows for three-phase operation. It has a continuous current rating of 40 A and a fixed trip setting. The frame is NEMA F-Frame with a fixed panel mounting styl
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for versatility, this breaker features three poles and provides reverse feed protection functions. It connects through feed-thru and includes terminal lugs for load-side connections and a busbar for line-side connections. It operates efficiently at frequencies ranging from 50 to 60 Hertz, c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal magnetic trip unit has fixed trip characteristics for both thermal and magnetic operations. It operates effectively at frequencies of 50/60 Hz and is compatible with molded case breakers. The device is easily field replaceable, identified by the trip type code T266.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is structured with three poles and a K-frame type, essential for heavy-duty tasks. It operates at a maximum voltage of 600 VAC and 250 VDC, with interrupting capacities of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. Its trip mechanism employs fixed thermal and fixed m
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Operating within a frequency range of 50 to 60 Hz, the GHB2040 includes a T186 trip type and is housed in a G frame size. This model provides an interrupt rating of 14 kAIC for 480Y/277 VAC and an impressive 65 kAIC at 240 VAC. It is configured with two poles for effective circuit protection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device has a fixed thermal and magnetic trip type, providing both long-time and instantaneous protection functions. The J Frame size ensures compatibility with various systems. The breaker features aluminum line and load side lugs for reliable connections and has an impressive interrupting capa
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features a T186 trip type and is housed in a frame designated as Frame J. It can handle an interrupt rating of 65 kAIC at 240 Vac and 35 kAIC at 480 Vac. Weighing 9.25 lbs, this unit utilizes aluminum for its terminals and supports wire sizes ranging from 4 AWG to 350
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit applies to three-pole configurations, designed for utilization in a J frame. It features a fixed thermal and adjustable magnetic trip type with a magnetic trip range of 350 to 700 A. Operational frequency ranges from 50 Hz to 60 Hz, making it adaptable to different sys
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a rated current of 15 A, suitable for various applications. It has an interrupting capacity of 14 kA at 480 V and 18 kA at 240 V. Supporting frequencies of 50 to 60 Hz, this breaker is specifically designed with load side terminals.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is engineered with fixed thermal and fixed magnetic trip types for dependable operation. The interrupting capacity is rated at 14 kAIC for 480Y/277 Vac and 65 kAIC at 240 Vac, suitable for handling substantial fault currents. It complies with UL certification standar