462 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a T186 trip type and designed in a G frame size, the GHB3070 has a three-pole configuration. It provides substantial protection with an interrupt rating of 65 kAIC at 240 VAC and 14 kAIC at 480Y/277 VAC. This breaker is suitable for installation at altitudes up to 1000 meters above sea lev
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accommodates a maximum of 480 VAC and 250 VDC, making it versatile for various applications. With a fixed thermal-magnetic trip mechanism, it ensures consistent protection against overloads. The EHD3060 includes load lugs for quick terminal connections and supports a 14 kA inter
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The LES3600LSIG accessory operates within L-frame circuit breakers, supporting up to three poles and rated for 600 amperes. It offers true RMS sensing capabilities, ensuring accurate current measurements. This unit includes thermal memory and mounts conveniently with a plug-in design, functioning ef
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Specifically designed for the Series C Circuit Breakers, the JT3100T offers three poles and operates at a rated voltage of 600 V AC and 250 V DC. The trip unit features a T186 trip type and is housed within a frame size categorized as J-K, making it compatible with various circuit configurations.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This thermal magnetic trip unit has fixed trip characteristics for both thermal and magnetic operations. It operates effectively at frequencies of 50/60 Hz and is compatible with molded case breakers. The device is easily field replaceable, identified by the trip type code T266.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This switch comes with three poles and a K Frame type designation, allowing for versatile installations. It features high instantaneous magnetic override for self-protection and maintains a maximum interrupting capacity of 65 kA at 240 Volts and 35 kA at 480 Volts. The operating temperature range is
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed from aluminum, this line and load terminal kit features two barrels and is intended for use in 3-phase applications. Rated for 600 volts AC, it accommodates wire sizes ranging from 400 to 500 thousand circular mils. The device complies with relevant safety standards, being UL-certified,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a T186 trip type and is structured with a robust L frame. It is designed for three-pole configurations and accommodates line and load connections with terminals made from aluminum. Its frequency operational range is set between 50 Hz and 60 Hz, ensuring versatility in v
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designated for motor protection, this circuit breaker features a magnetic trip range of 9 to 30 Amps. It is constructed with a J-K frame and incorporates non-aluminum terminal materials, enhancing durability. Certified by UL and CSA, it operates effectively at temperatures between 0 to 40 degrees Ce
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a nominal voltage ranging from 125 to 250 Volts DC and 277 to 480 Volts AC. It is rated for an interrupt capacity of 65 kA at 240 Volts AC and 14 kA at higher voltages. The GHB2050 features a G frame design with two poles and operates at frequency ratings of 50 to