Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The GHB3090S1 features a three-pole configuration and operates within a frequency range of 50 to 60 Hz. This circuit breaker employs fixed thermal and magnetic trip mechanisms for enhanced safety and reliability. It has a weight of 1.7 lbs and is designed for bolt-on mounting, ensuring secure instal
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for field mounting on the left pole, the UVH1LP11K is compatible with several F-Frame types, including FDB, FD, HFD, FDC, E2F, and E2FM. It operates effectively at 50/60 Hz and connects using pigtail leads. The device is certified under UL 1066, UL 489, and ANSI C37 standards, ensuring reli
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This alarm switch operates within a temperature range of 0°C to 40°C for both active use and storage. It can withstand humidity levels up to 80% without condensation and is rated for installation at altitudes up to 1000 meters above sea level. The contact configuration includes 1M/1B, allowing for v
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a 2-pole configuration and incorporates fixed thermal and magnetic trip types. It's designed to function within a relative humidity range of 5% to 95% without condensation, ensuring reliable operation in varying environments.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed as part of the Series C lineup and is classified under the KDB type with a frame size of K-Frame. The configuration is a complete breaker with three poles and a thermal-magnetic trip mechanism. Rated for both AC and DC applications, it boasts an interrupting capacity
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and includes load-side standard pressure lugs for easy installation. Its interrupting capacities are notable, with ratings of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. The trip type combines fixed thermal and fixed ma
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker, featuring three poles, operates effectively in a three-phase setting. It has a weight of 4.4 lbs and a voltage rating of up to 600 VAC for AC and 250 VDC for DC applications. The interrupting capacity is rated at 100 kAIC for 240 VAC and 65 kAIC for 480 VAC, ensuring robust fau
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a capacity for handling currents of 50 A, the HFD3050L circuit breaker operates efficiently, boasting a fixed thermal and magnetic trip type. It achieves an interrupting rating of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring safety in demanding environments. This unit is tailored for th
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is equipped with two poles and includes feed-thru connection types with line and load lugs. It offers both long-time and instantaneous trip functions through its thermal magnetic trip type. The breaker has an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at