Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features two poles for effective circuit management. It is rated for 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, providing robust performance under fault conditions. The EHD2080L is built with fixed thermal and fixed magnetic trip types for reliable operations and is suitable for 50 to 60 H
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole breaker is housed within a Frame G and features a trip type of T186. It can handle frequency ratings of both 50 and 60 Hz, and offers impressive interrupt ratings of 65 kAIC at 240 Vac and 14 kAIC at 480Y/277 Vac. The unit is bolt-mounted and accommodates wire sizes ranging from 14 A
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker features an AC voltage rating of 600 VAC and a DC rating of 250 VDC. It includes thermal-magnetic trip units with long-time and instantaneous functions. The device is rated to interrupt currents up to 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at 600 VAC, e
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker features a NG-Frame construction and operates effectively in a frequency range from 50 Hz to 60 Hz. It has a commendable interrupting capacity of up to 100 kAIC at 240 VAC, decreasing to 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. The device offers trip functions tha
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Built within the Series C line, this circuit breaker features three poles and incorporates both fixed thermal and fixed magnetic trip types. The KG3400 has an interrupting capacity of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, ensuring dependable performance against fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker supports three poles and is rated for 600 VAC in AC applications and 250 VDC in DC applications. The interrupting capacity is rated at 64 kA at 480 VAC. Magnetic-only trip settings allow for a trip range of 450 A to 1500 A, with terminals designed for easy connection on both lin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit includes three poles and exhibits a robust frame type classified as F-frame. The HFD3030V also supports a frequency range between 50 and 60 Hz for versatile applications. With fixed thermal and magnetic trip technology, it ensures reliable protection. It has an interrupting capacity of 100
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features three poles and is designed with thermal magnetic trip technology, providing both long-time and instantaneous trip functions. The MT3600T trip unit has an interrupting rating of 65 kAIC at 240 VAC, 50 kAIC at 480 VAC, and 25 kAIC at 600 VAC. Designed for standard environmental con
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This breaker comprises three poles and is specifically designed for three-phase systems. It features a trip function of LI, providing long-time and instantaneous protection. Its robust design includes an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring safe operation und
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit is rated for two poles and operates efficiently within a frequency range of 50 to 60 Hz. Its insulation voltage is rated at 600 VAC with a withstand voltage of 8 kV. It is built to perform in environments with up to 95% humidity and is suited for altitudes of up to 2000 meters.