404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and employs a fixed thermal and fixed magnetic trip mechanism. It offers a 200 kA interrupt rating at 240 V and 100 kA at 480 V, ensuring reliable performance under fault conditions. Rated for voltages up to 600 Vac and 250 Vdc, the LDC3600 is suitable for a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a maximum voltage capacity of 600 VAC, this circuit breaker utilizes a fixed instantaneous trip adjustment. It boasts an interrupting capacity of 35 kAIC at 480 VAC and operates efficiently at 50/60 Hz. The construction features a bolt-on mounting style, and the typical electrical endurance all
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker utilizes fixed thermal-magnetic trip technology for enhanced performance. Its interrupting ratings include 14 kA at 480Y/277 VAC and 65 kA at 240 VAC. Suitable for mounting via a bolt-on bus method, the GHB3015S1 supports an operating frequency of 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is compatible with both AC and DC applications, supporting 600 VAC and 250 VDC respectively. It offers panel mounting through a bolt-on method and comes equipped with buss bar connections for the line side and lugs for the load side. Its interrupting cap
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug is compatible with various frames, including LD, HLD, LDB, and others in the Series C lineup. It is built to function within a temperature range from 0°C to 40°C and supports both operating and storage humidity levels of 80% (non-condensing).
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles and features an electronic LSG trip type for enhanced safety. It is rated for frequencies between 50 Hz and 60 Hz. This device functions correctly in environments with humidity levels of up to 80% without condensation. The frame type is classified as F.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and an AIC rating of 65 kA at 480 volts, which provides robust fault protection. It is designed for high humidity environments, supporting both storage and operating conditions at 80% non-condensing humidity. With a maximum installation altitude of 1000 MSL,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The JD3070 features three poles and a T 186 trip type. This unit is compatible with operation at frequencies ranging from 50 to 60 Hz. It offers robust interrupt ratings of 35 KAIC at 480 V and 65 KAIC at 240 V, ensuring reliable circuit protection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is mounted for field use on the left pole. It has an F Frame type and connects via pigtail leads. The UVH1LP03K operates within a temperature range of 0°C to 40°C and can be installed at altitudes up to 1000 meters above sea level. Both operating and storage conditions maintain
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This 2-pole circuit breaker features an interrupt rating of 200 kAIC at 240V and 100 kAIC at 480V. It is designed for use with 600 VAC and 250 VDC systems. This device supports a frequency range of 50/60 Hz, ensuring compatibility with a variety of electrical setups. The load-side terminal configura