The 1336 Drives are microprocessor controlled, high performance, adjustable frequency drive which are designed to be used to control three phase induction motors for critical industrial applications. The drive also produces a three phase, PWM, adjustable frequency output to supply an adjustable motor speed. These drives output voltage is a function of output frequency and is adjustable to match motor parameters to obtain the optimum motor performance.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 1336 Adjustable

Browse available units in our catalog of 1336 Adjustable.

1336-CONV-SP6A

The 1336-CONV-SP6A upgrade kit is an upgrade kit designed to be used with adjustable frequency AC drives from the 1336 Plus, Force, and Impact series by Allen-Bradley/Rockwell Automation. These 3 seri

Call
4.9

1336-BDBMX3-SP17D

This printed circuit board is designed for 3-phase applications and is compatible with frames A through E. It features six digital inputs and two analog inputs, making it suitable for a wide range of

Call
4.9

1336-BDBMX3-SP1D

This part functions as a gate drive board with a voltage rating of 480 V and a horsepower capacity of 7.5 Hp. It operates effectively between 0°C and 50°C and can be stored from -40°C to 85°C. The boa

Call
4.9

1336-BDBMX3-SP2D

Designed for use within the 1336 PLUS, 1336 PLUS II, 1336 FORCE, and 1336 IMPACT series, this gate drive board operates efficiently within a temperature spectrum of 0°C to 40°C. It also allows for sto

Call
4.8

1336-F1-SP15A

This DC bus fuse operates efficiently at an AC voltage rating of 480V and a DC voltage range of 600 to 650 volts. It is designed to function within an operating temperature span of 0°C to 40°C. The de

Call
4.5

1336-F1-SP17A

This snubber PCB is designed to function efficiently in 3-phase applications while accommodating frequencies between 50 and 60 Hz. It has an enclosure rating of NEMA 1, providing essential protection,

Call
4.9

1336-F2-SP5A

This input line fuse is applicable for drives such as PLUS, PLUS II, FORCE, IMPACT, and REGEN. Each drive requires three kits for proper installation. The component operates in environments with tempe

Call
4.7

1336-GF-SP2A

The 1336-GF-SP2A transformer is a current transformer that has been designed and developed by Allen-Bradley/Rockwell Automation to be used with the 1336 Plus, Impact, Regen, and Plus II series of adju

Call
4.5

1336-MOD-FC3

This operator interface panel has a robust NEMA 4 enclosure rating, ensuring protection against dust and water ingress, with an IP66 rating for additional safeguarding. It operates with a voltage comp

Call
4.5

1336-RFB-7-AA

This radio frequency interference filter is suited for 3-phase systems and operates within an input frequency range of 50 Hz to 60 Hz. With an IP20 rating, it is intended for use in open type enclosur

Call
4.7
Showing 261-270 of 313 results

About 1336 Adjustable

The 1336 Adjustable series is a series of drives manufactured by Allen-Bradley. The 1336 Adjustable drives are microprocessor-controlled drives that are known to produce the high-level performance that is required for controlling the 3-phase induction motors. The 1336 Adjustable drives are critical for various industrial applications. The 1336 Adjustable drives produce the 3-phase PWM adjustable frequency output for supplying adjustable motor speed. The output of the 1336 Adjustable drives is a function of the output frequency and it is usually adjustable to ensure an exact match to the motor parameters. The 1336 Adjustable drives have been designed as constant torque, adjustable speed control drives and they come with 150% overload capability. The drives under the 1336 Adjustable drives series are adaptable through programming to handle a wide variety of applications.

The 1336 Adjustable series drives feature units that are specially designed to produce an exceptional output voltage with the current waveform. Before deploying the unit with an inverter, notice any special considerations that may be present in the installation area. Note that slow speeds might result in problems related to cooling due to the reduction in the fan rotation speed. The 1336 Adjustable drives could overheat if they are operated at a highly rated torque for long periods. The 1336 Adjustable drives come equipped with the MOV or the Metal Oxide Varistor, providing voltage surge protection. The MOV circuit is also designed for surge suppression only and not for continuous operation. The 1336 Adjustable drives support user parameters for selecting and controlling the operations of the drives. To ensure optimal performance, make sure that the whole system is correctly applied or installed.