140G-G2E3-D16
The 140G-G2E3-D16 Molded Case Circuit Breaker has a Adjust Thermal/ Fixed Magnetic Protection Type and a 2.42 lb Weight.
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
The 140G-G2E3-D16 Molded Case Circuit Breaker has a Adjust Thermal/ Fixed Magnetic Protection Type and a 2.42 lb Weight.
This J-frame circuit breaker supports adjustable thermal and magnetic protection settings. It has a current capability set at 250 Amps and withstands insulation voltages of up to 1000 V. The 140G-J3F3
The 140G-G2C4-C63 is a molded case circuit breaker belonging to Allen Bradley's G frame series. It has a current rating of 125 Amps and operates with a maximum interrupting capacity of 25 kA. The brea
This circuit breaker features a G frame size and operates at a rated voltage of 800 V. It employs bolt connections for secure attachment, with connection points positioned on the front side for easy a
The 140G-H6C3-C60 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.
The 140G-M0X3 Molded Case Circuit Breaker has a Breaker Frame Protection Type and a 26.68 lb Weight.
The 140G-H6C3-C15 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.
The 140G-KTH3-D40 Molded Case Circuit Breaker has a Electronic LSI Protection Type and a 7.17 lb Weight.
This device operates with a fixed thermal trip setting of 35 A and a magnetic trip rating reaching up to 500 A. Designed for applications requiring reliable protection, its current range extends up to
This circuit breaker is built for efficient protection with breaking frame technology. It operates at a rated insulation voltage of 1000 volts and withstands impulse voltages up to 8 kV. At 7.17 pound
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.