Free UPS Ground on All Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

140G-K0X3

This circuit breaker is built for efficient protection with breaking frame technology. It operates at a rated insulation voltage of 1000 volts and withstands impulse voltages up to 8 kV. At 7.17 pound

In Stock Ships Today
4.9

140G-H6C3-C35

The 140G-H6C3-C35 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

Available
5.0

140G-G2C4-C20

The 140G-G2C4-C20 model is a molded case circuit breaker featuring a G frame rated for 125 amps. It is equipped with four poles and supports fixed thermal and magnetic protection mechanisms, ensuring

Available
4.8

140G-G3C3-C45

The 140G-G3C3-C45, a product classified under molded case circuit breakers, features a unique G frame design. This device supports a maximum current capacity of 125 Amps and can handle a continuous lo

In Stock Ships Today
4.7

140G-G6C3-C45

The 140G-G6C3-C45 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.42 lb Weight.

In Stock Ships Tomorrow
4.4

140G-I2C3-D15

This molded case circuit breaker has a rating of 25 kA for interrupting current. The thermal and magnetic trip mechanisms are fixed at 150 A and 1500 A, respectively. The rated insulation voltage stan

Call
4.4

140G-H6C3-C15

The 140G-H6C3-C15 Molded Case Circuit Breaker has a Fixed Thermal/ Fixed Magnetic Protection Type and a 2.65 lb Weight.

Available
5.0

140G-J6F3-D22

The 140G-J6F3-D22 Molded Case Circuit Breaker has a Adjust Thermal/ Adjust Magnetic Protection Type and a 5.51 lb Weight.

Call
4.5

140G-G2C4-C50

The Allen-Bradley 140G-G2C4-C50 is a molded case circuit breaker designed within the 140G MCB series. It features a four-pole configuration and offers a current range of up to 50 amps, providing robus

Available
4.6

140G-MTF3-D80

This circuit breaker is part of the M frame type and includes a trip unit for its interrupting rating. It is designed for a current range of 800 A, weighing 26.68 pounds. The device can endure a mecha

Available
5.0
Showing 101-110 of 1,219 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.