140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J3H3-C60 from the 140G MCB series.
    Allen Bradley

    140G-J3H3-C60

    This circuit breaker operates within a current range of 60 A and is designed with an insulation voltage rating of up to 1000 V. It can handle impulse voltages of 8 kV and is housed in a J frame. Weigh

    Available
    Call
  • 140G-J3I4-C60 from the 140G MCB series.
    Allen Bradley

    140G-J3I4-C60

    This circuit breaker features a four-pole configuration and operates within a current range of 60 A. It has a rated insulation voltage of 1000 V and an impulse withstand voltage rating of 8 kV. Weighi

    Available
    Call
  • 140G-J6H4-C60 from the 140G MCB series.
    Allen Bradley

    140G-J6H4-C60

    Designed with four poles, the 140G-J6H4-C60 operates within a current range of 60 Amps. It boasts a rated insulation voltage of 1000 volts, with an impulse withstand voltage rating of 8 kV. This circu

    Available
    Call
  • 140G-JC0C3-C70 from the 140G MCB series.
    Allen Bradley

    140G-JC0C3-C70

    This circuit breaker supports fixed thermal and magnetic protection mechanisms, featuring a current range of 70 A. It can withstand a rated insulation voltage of 1000 V and impulse voltages of up to 8

    Available
    Call
  • 140G-JC6C3-C25 from the 140G MCB series.
    Allen Bradley

    140G-JC6C3-C25

    This breaker features a JC frame and operates at a fixed thermal and magnetic protection type with a current range of 25 Amps. It can withstand rated insulation voltages of up to 1000 Volts and can en

    Available
    Call
  • 140G-JC6F3-D10 from the 140G MCB series.
    Allen Bradley

    140G-JC6F3-D10

    With a rated insulation voltage of 1000V, this molded case circuit breaker is suitable for a variety of electrical environments. It operates within a current range of 100 A and boasts an impulse withs

    Available
    Call
  • 140G-JC6H3-D10 from the 140G MCB series.
    Allen Bradley

    140G-JC6H3-D10

    This circuit breaker operates within a current range of up to 100 A. It is equipped with electronic LSI protection to enhance reliability. The device can handle insulation voltages up to 1000 V and wi

    Available
    Call
  • 140G-JTF4-D16 from the 140G MCB series.
    Allen Bradley

    140G-JTF4-D16

    This circuit breaker maintains four poles and includes adjustable thermal and magnetic protection. It also supports a rated insulation voltage of 1000 volts and withstands impulse voltages of 8 kV. Th

    Available
    Call
  • 140G-JTI4-C60 from the 140G MCB series.
    Allen Bradley

    140G-JTI4-C60

    This molded case circuit breaker operates with four poles and supports a rated current of 60 amps. It is configured for a rated insulation voltage of 1000 volts and withstands impulse voltages of up t

    Available
    Call
  • 140G-K6K4-D40 from the 140G MCB series.
    Allen Bradley

    140G-K6K4-D40

    This Allen Bradley circuit breaker operates at a voltage rating of up to 1000 volts. Additionally, it has a rated current range of 400 amps. The unit provides a rated impulse withstand voltage of 8 kV

    Available
    Call
Showing 1,011-1,020 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.