140G-NS5K4-E12
This device features an NS frame size built to accommodate four poles. It operates effectively within a current range of 1200 A. The rated insulation voltage is 1000 volts, and it can withstand impuls
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This device features an NS frame size built to accommodate four poles. It operates effectively within a current range of 1200 A. The rated insulation voltage is 1000 volts, and it can withstand impuls
This four-pole circuit breaker operates within a current range of 2000 A and is rated for insulation voltages of 1000 volts. It can withstand impulse voltages up to 12 kV. With a weight of 175 pounds,
Designed with a frame size of H, the 140G-H0F3-D11 circuit breaker can handle interruptions up to 100 kA. This unit supports a current range of 110 Amps. The insulation voltage rating is 1000 Volts, a
This circuit breaker is structured on the H-frame design, accommodating a current range of 63 amps. It consists of four poles and offers robust insulation with a rated voltage of 1000 V. Additionally,
The 140G-H2H3-D10 functions within a range of 100 Amps and uses electronic LSI protection for reliable operation. This circuit breaker has a rated insulation voltage of 1000 V and can withstand impuls
This four-pole device operates within an H frame and features Electronic LSIG protection. It functions effectively across a current range up to 60 A. The rated insulation voltage is 1000 V, and it can
Crafted with an H frame, the 140G-H3F4-D10 offers reliable overcurrent protection utilizing adjustable thermal and magnetic trip settings. It features four poles with a current handling capability of
The 140G-H3I4-C60 circuit breaker features a maximum rated insulation voltage of 1000 Volts and can withstand impulse voltages of up to 8 kV. It operates within a current range of 60 Amps and boasts a
This circuit breaker operates within a current range of 70 Amps. It employs fixed thermal and magnetic protection types to prevent electrical faults. Rated for insulation voltages of 1000 V and able t
This unit employs fixed thermal and magnetic protection, ensuring reliability. It supports a current range of 63 A and is rated for 800V insulation voltage. The impulse withstand voltage is specified
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.