Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392
140G MCB

Allen Bradley 140G MCB

The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 140G MCB

Browse available units in our catalog of 140G MCB.

  • 140G-J6C4-C70 from the 140G MCB series.
    Allen Bradley

    140G-J6C4-C70

    The 140G-J6C4-C70 features four poles and operates under fixed thermal and magnetic protection. This circuit breaker can manage loads within a current range of 70 A. It is rated for an insulation volt

    Available
    Call
  • 140G-H2F4-C90 from the 140G MCB series.
    Allen Bradley

    140G-H2F4-C90

    This 4-pole circuit breaker operates at a current range of 90 A and has adjustable thermal and magnetic protection. It is rated for an insulation voltage of 1000 V and can withstand impulse voltages u

    Available
    Call
  • 140G-H3H4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H3H4-D16

    This circuit breaker, classified as H-frame, supports a current range of 160 Amps. It possesses an interrupting rating of 35 kA, ideal for managing significant fault currents. With a rated insulation

    Available
    Call
  • 140G-H6H4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H6H4-D16

    This circuit breaker features four poles and operates within a current range of 16 A. It implements electronic LSI protection for advanced monitoring and control. Rated insulation voltage is 1000 V, a

    Available
    Call
  • 140G-H6I4-D16 from the 140G MCB series.
    Allen Bradley

    140G-H6I4-D16

    This circuit breaker features four poles and handles a current range of 160 A. It is rated for insulation voltage up to 1000 V and can withstand impulse voltages of 8 kV. The piece weighs 3.53 lbs and

    Available
    Call
  • 140G-HC0C3-C35 from the 140G MCB series.
    Allen Bradley

    140G-HC0C3-C35

    This circuit breaker supports a current range of 35 A and is rated for insulation up to 1000V. The impulse withstand voltage is rated at 8 kV, providing enhanced durability. Weighing 2.65 lb, it demon

    Available
    Call
  • 140G-HC0I3-C25 from the 140G MCB series.
    Allen Bradley

    140G-HC0I3-C25

    This device operates within a current range of 25 Amps and offers an outstanding rated insulation voltage of 1000 volts. Additionally, it has a rated impulse withstand capability of 8 kV, ensuring res

    Available
    Call
  • 140G-HC6I3-C25 from the 140G MCB series.
    Allen Bradley

    140G-HC6I3-C25

    The 140G-HC6I3-C25 molded case circuit breaker features current capabilities within the range of 25 A. It operates under a rated insulation voltage of 1000V and can endure impulse withstand voltages u

    Available
    Call
  • 140G-HC6I3-D12 from the 140G MCB series.
    Allen Bradley

    140G-HC6I3-D12

    Designed with a frame type HC, this circuit breaker employs electronic LSIG protection. It has a current range up to 120 A and a rated insulation voltage of 1000 V. The impulse withstand voltage is ra

    Available
    Call
  • 140G-HTF4-C80 from the 140G MCB series.
    Allen Bradley

    140G-HTF4-C80

    This product is classified as a four-pole circuit breaker and operates effectively within an adjustable current range of 80 A. It offers rated insulation up to 1000 volts and can withstand impulse vol

    Available
    Call
Showing 991-1,000 of 1,222 results

About 140G MCB

The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.

The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.