140G-I2C4-C80
This unit, supporting four poles, operates within a current range of 80 Amps. It offers fixed thermal and magnetic protection, with an insulation voltage rated at 800 volts and an impulse withstand vo
The Allen Bradley 140G molded case circuit breakers are suitable for a wide range of applications in low-voltage 3-phase power systems. 140G series circuit breakers can be reverse-fed. They provide overcurrent protection to conductors and other equipment, and they can be used as the main disconnecting devices for control panels. The 140G circuit breakers can also be used for branch circuit protection or as feeder breakers.
Browse available units in our catalog of 140G MCB.
This unit, supporting four poles, operates within a current range of 80 Amps. It offers fixed thermal and magnetic protection, with an insulation voltage rated at 800 volts and an impulse withstand vo
This circuit breaker features four poles and operates within a current range of 110 A. It is designed for a rated insulation voltage of 800 V and has an impulse withstand rating of 8 kV. Weighing 5.73
This unit accommodates a current range of 80 A and offers adjustable thermal and magnetic protection. It can handle a rated insulation voltage of 1000 V and withstand impulse voltages of up to 8 kV. W
The 140G-J0F4-D25 molded case circuit breaker is configured with four poles and offers adjustable thermal and magnetic protection mechanisms. Its insulation voltage rating reaches up to 1000 volts, an
This circuit breaker operates with fixed thermal and fixed magnetic protection technology. It supports a current rating of 60 Amps and up to 250 Amps of maximum current and is rated for up to 1000 vol
The 140G-J2F4-D10 includes four poles, a type J frame, and adjustable thermal and magnetic protection mechanisms. It supports a current rating of 100 A and up to 250 A of maximum current. It also supp
This circuit breaker is designed with four poles and can handle a current rating of up to 250 A. It features a rated insulation voltage of 1000 volts and a rated impulse withstand voltage of 8 kV, ens
As part of the 140G series, this circuit breaker employs four poles and has a fixed thermal and magnetic protection system. The 140G-J3C4-C30 breaker has a maximum interrupting rating of 35 kA. It fea
This device is categorized under the J frame and provides an interrupting capacity of 35 kA. The breaker operates within a current range of 150 A, with a rated insulation voltage of 1000 V. It withsta
This unit supports a four-pole configuration and operates at a rated insulation voltage of 1000 volts. Its impulse withstand voltage reaches 8 kV, ensuring reliability in harsh conditions. Weighing in
The Allen-Bradley/Rockwell Automation 140G MCB series is a series of molded case circuit breakers. According to the National Electrical Manufacturers Association (NEMA), a circuit breaker is a device designed to open and close a circuit by non-automatic means, and to open the circuit automatically at a predetermined overcurrent level without injury to itself when it is properly applied within its rating. The 140G MCB circuit breakers employ different methods to control the operating mechanisms. These methods include stored energy operation, dependent manual/power operation, and independent manual/power operation. When breakers in the 140G MCB family encounter an overcurrent, they can use instantaneous, inverse time delay, and definite time delay overcurrent releases. All these breakers from the Allen-Bradley 140G series of molded-case circuit breakers come with a frame rating of 125 Amps and an interrupting capacity that goes from 25 to 65 kA.
The Allen-Bradley 140G MCB series of circuit breakers are CCC, UL, and CSA certified since they comply with international standards such as the UL, CSA, and IEC standards. Since these circuit breakers have molded cases, they provide short circuit and thermal overcurrent protection by using either mechanical or electronic means. Note that the mechanical means use heater elements to detect the current flow and model the associated heat generated by the current. Additionally, molded case circuit breakers in this family feature either fixed or adjustable trip units. Whether they use fixed or adjustable magnetic and thermal trip units, the motor current rating of these circuit breakers should be less than or equal to 250% of the motor’s full-load ampere rating, or less than or equal to 300% for motors with a current of less than or equal to 100 amperes if the circuit trips on startup. Also, a circuit breaker in the 140G MCB series can be used with a motor current rating of less than 400% for motors with a current rating of more than or equal to 100 Amps if the circuit breaker trips on startup. The safety features of these breakers are capable of preventing accidents such as fires and explosions due to over-current or the overheating of conduits.